Logo del repository
  1. Home
 
Opzioni

Long-Term Outcomes in ICD: All-Causes Mortality and First Appropriate Intervention in Ischemic and Nonischemic Etiologies

Cittar, Marco
•
Zecchin, Massimo
•
Merlo, Marco
altro
Sinagra, Gianfranco
2024
  • journal article

Periodico
THE AMERICAN JOURNAL OF CARDIOLOGY
Abstract
Real-life data comparing the long-term outcome in patients with different heart diseases carrying an implantable cardioverter defibrillator (ICD) are scarce. This study aimed to compare the long-term risk of the first appropriate ICD intervention and overall survival in patients with ICD and heart disease of different etiologies. Patients with an ICD implanted between January 1, 2010, and December 31, 2022, followed in our center were included. Study outcomes were all-cause mortality and first appropriate ICD intervention. A comparison between ischemic heart disease (IHD) and non-IHD (NIHD) was performed. In NIHD different etiologies of dilated cardiomyopathy (DCM) were analyzed. Overall, 1184 patients (592 IDH; 592 NIHD) were included. During a median follow-up of 53 months all-cause death occurred in 399 patients (34%) whereas first appropriate ICD intervention occurred in 320 (27%). All-cause mortality was significantly higher in IHD vs NIHD patients (60% vs 43%; p <0.0001) but no differences in appropriate ICD intervention rate at 10 years (34% vs 40%; p = 0.125) were observed. In patients with NIHD, a higher 10-year mortality rate was found in valvular heart disease, post-radio/chemotherapy DCM (rctDCM), and hypertensive DCM. Hypertrophic cardiomyopathy, alcoholic DCM, and rctDCM were the least arrhythmic phenotypes in NIHD. Of note, inappropriate interventions in alcoholic DCM and rctDCM were higher than appropriate ones. In conclusion, the rate of ICD-appropriate interventions and mortality is different according to the etiology of heart disease and cardiovascular risk profile; this should be taken into consideration in the prognostic stratification of these patients at the time of implantation.
DOI
10.1016/j.amjcard.2024.09.026
WOS
WOS:001342154100001
Archivio
https://hdl.handle.net/11368/3095398
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85206844359
https://www.sciencedirect.com/science/article/pii/S0002914924007045
Diritti
closed access
license:copyright editore
license:copyright editore
license uri:iris.pri02
license uri:iris.pri02
FVG url
https://arts.units.it/request-item?handle=11368/3095398
Soggetti
  • all-cause mortality

  • appropriate

  • etiologie

  • implantable cardiover...

  • inappropriate

  • nonischemic

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback