Logo del repository
  1. Home
 
Opzioni

Subfoveal choroidal blood flow and central retinal function in early glaucoma

MARANGONI D
•
Falsini Benedetto
•
Colotto Alberto
altro
Riva Charles E.
2012
  • journal article

Periodico
ACTA OPHTHALMOLOGICA
Abstract
PURPOSE: To assess subfoveal choroidal blood flow (ChBF) in patients with early manifest glaucoma (EMG) and to compare blood flow with functional measures of central retinal integrity, standard automated perimetry (SAP) and pattern electroretinogram (PERG). METHODS: Subfoveal ChBF was determined by confocal, real-time laser Doppler flowmetry in 24 patients with EMG [>-6 dB mean deviation (MD), age range: 29-77 years, visual acuity: 20/25-20/20] and 23 age-matched control subjects. All patients had a therapeutically (topical beta-blockers with or without prostaglandin analogues) controlled intraocular pressure (IOP < 20 mmHg). Subfoveal choroidal blood volume (ChBVol), velocity (ChBVel) and ChBF were determined as the average of three 60 second recordings. In all patients and controls, the PERG and SAP (Humphrey 30-2), following standardized protocols, were also recorded. RESULTS: In patients with EMG, reductions in average ChBVel and ChBF were roughly equal, respectively, by 30% and 33.4% (p < 0.01), when compared to control subjects, so that there was no significant difference in ChBVol between the two groups. Pattern electroretinogram amplitudes were reduced by 46% (p < 0.01) in patients compared to controls. No correlation was found between any of the ChBF parameters and PERG amplitude, or Humphrey 30-2 MD and pattern standard deviation. CONCLUSION: The results suggest a significant alteration of both ChBVel and ChBF in EMG, which does not appear to be associated with the severity of central retinal dysfunction. These findings may contribute to a better understanding of the pathophysiology of early glaucomatous damage in EMG and have implications for the treatment of this pathologic condition.
DOI
10.1111/j.1755-3768.2011.02340.x
WOS
WOS:000306903100006
Archivio
http://hdl.handle.net/11368/3002708
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84861613393
Diritti
metadata only access
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback