Logo del repository
  1. Home
 
Opzioni

Evaluation of the Efficacy of Different Mechanical Inter‐Dental Devices Around Single Implant Prosthetic Crowns: In Vitro Study

Lorenzo Bevilacqua
•
Simone Poncato
•
Antonietta Scarazzato
altro
Michele Maglione
2026
  • journal article

Periodico
INTERNATIONAL JOURNAL OF DENTAL HYGIENE
Abstract
Objectives: The aim of the study was to analyse the effectiveness of some interproximal tools to remove bacterial biofilm on implant-prosthesis rehabilitations with different morphological characteristics. Methods: 3 temporary crowns made by polymethylmethacrylate resin with different emergency profiles (20°, 30° and 40°) screwed onto an implant placed on a resin model at different implant depth relative to bone crest (bone level, subcresal at 1 mm, supracrestal at 1 mm). After coating surfaces with a contact detection spray, the screwed crowns were cleaned with different interproximal tools: the Oral-B Super FlossTM, the TePe Bridges & Implant Floss, the cylindrical brush TePe Original, the conical brush GUM TRAV-LER and the TePe EasyPickTM soft pick. At the end of each use the crowns were photographed and analysed using TextCompare software. For each tool, five measurements were taken per interproximal surface. The data were analysed statistically. Results: All the tools were effective in reducing the interproximal plaque. Lower results were obtained by the TePe EasyPickTM soft pick (min-max cleaned surface 47%–68%). In implant-prosthesis with emergence angles below 30° the interproximal brushes were more efficient (cleaned area min-max 74%–75%), while with greater angles implant floss was more effective (cleaned area min-max 73%–76%). Conclusion: Brushes for smaller emergence profiles and subcrestal implants and floss for crowns with larger emergence profiles and supracrestal implants are recommended.
DOI
10.1111/idh.70013
WOS
WOS:001630489300001
Archivio
https://hdl.handle.net/11368/3122060
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-105024009296
https://onlinelibrary.wiley.com/doi/10.1111/idh.70013
https://ricerca.unityfvg.it/handle/11368/3122060
Diritti
closed access
license:copyright editore
license uri:iris.pri02
FVG url
https://arts.units.it/request-item?handle=11368/3122060
Soggetti
  • dental flo

  • emergence profile

  • implant

  • inter-dental brushe

  • inter-dental cleaning...

  • prosthetic crown

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback