Noninvasive techniques for blood pressure measurement are not a reliable alternative to direct measurement: a randomized crossover trial in ICU

Ribezzo S
•
Spina E
•
Di Bartolomeo S
•
Sanson G
2014
  • journal article

Periodico
THE SCIENTIFIC WORLD JOURNAL
Abstract
Introduction. Noninvasive blood pressure (NIBP) monitoring methods are widely used in critically ill patients despite poor evidence of their accuracy. The erroneous interpretations of blood pressure (BP) may lead to clinical errors. Objectives. To test the accuracy and reliability of aneroid (ABP) and oscillometric (OBP) devices compared to the invasive BP (IBP) monitoring in an ICU population. Materials and Methods. Fifty adult patients (200 comparisons) were included in a randomized crossover trial. BP was recorded simultaneously by IBP and either by ABP or by OBP, taking IBP as gold standard. Results. Compared with ABP, IBP systolic values were significantly higher (mean difference ± standard deviation 9.74±13.8; P<0.0001). Both diastolic (-5.13±7.1; P<0.0001) and mean (-2.14±7.1; P0.0033) IBP were instead lower. Compared with OBP, systolic (10.80±14.9; P<0.0001) and mean (5.36±7.1; P<0.0001) IBP were higher, while diastolic IBP (-3.62±6.0; P<0.0001) was lower. Bland-Altman plots showed wide limits of agreement in both NIBP-IBP comparisons. Conclusions. BP measurements with different devices produced significantly different results. Since in critically ill patients the importance of BP readings is often crucial, noninvasive techniques cannot be regarded as reliable alternatives to direct measurements.
DOI
10.1155/2014/353628
WOS
WOS:000330876400001
Archivio
http://hdl.handle.net/11368/2933642
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84896862853
Diritti
metadata only access
Soggetti
  • CRITICALLY-ILL PATIEN...

  • ARTERIAL

  • Blood pressure

  • Invasive

  • Oscillometric

  • ACCURACY

  • ARM

  • DEVICE

Web of Science© citazioni
55
Data di acquisizione
Mar 23, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback