Mechanical and fatigue resistance of restorations supported by welded- framework and realized using computer-aided designed prosthetic shells: In vitro pilot study

Albiero, Alberto Maria
•
Bevilacqua, Lorenzo
•
Pegoraro, Federica
altro
Maglione Michele
2024
  • journal article

Periodico
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS. PART H, JOURNAL OF ENGINEERING IN MEDICINE
Abstract
Resin coating in implants rehabilitation cannot always be aesthetic, durable and comfortable for the patient mainly due to the limited dimensions of the final structure. Intraoral welding technique and computer-aided designed prosthetic shells may be a solution. This in vitro study evaluates the capacity of load and the weakest point of implant-supported provisional prosthesis using welded titanium framework. Twelve samples were produced to simulate an implant sup- ported fixed prosthetic bridge. Two implants (Ankylos; Dentsply Sirona Implants; Germany) were inserted inside blocks of nanoceramic material produced with a stereolithographic 3D printer. A polymethylmethacrylate (PMMA) resin shell was performed with CAD/CAM and relined on welded framework. Six samples were produced with the same proce- dure reducing resin thickness. The samples were subjected to fatigue test (6,500,000 cycles) using ElectroForce 3310 fatigue machine (t1); subsequently a mechanical compression test using a universal Shimadzu AGS-X 10 machine (t2). The samples were analyzed with a photographic and radiographic documentation at t0, t1 and t2. The samples survived mechanical fatigue test without evidence of failure. The radiographic and photographic evaluation revealed the fracture of resin coating after the mechanical compression test. The samples with minimal resin thickness fractured first. Adequate assessment of the resin thickness is mandatory to improve the longevity of these rehabilitations. CAD-CAM digital prosthetic design allows us to optimize the thicknesses and the prosthetic shapes, allowing us to obtain good degrees of resistance even in the presence of reduced prosthetic spaces.
DOI
10.1177/09544119231221189
WOS
WOS:001138496100001
Archivio
https://hdl.handle.net/11368/3067198
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85181683824
https://journals.sagepub.com/doi/10.1177/09544119231221189
Diritti
open access
license:copyright editore
license:digital rights management non definito
license uri:iris.pri02
license uri:iris.pri00
FVG url
https://arts.units.it/request-item?handle=11368/3067198
Soggetti
  • Welding

  • immediate loading

  • implant-supported den...

  • mechanical stre

  • CAD/CAM design

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback