Logo del repository
  1. Home
 
Opzioni

Interchangeability between two breath-by-breath O2 uptake calculation algorithms in asthmatic and healthy volunteers

Francescato M. P.
•
Canciani M.
•
Cettolo V.
2020
  • journal article

Periodico
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY
Abstract
Introduction: The interchangeability analysis has been recently proposed to objectively assess whether a newly developed measurement tool can substitute the older ones; this analysis assumes that the measures yielded by the compared tools should differ less than a maximum acceptable value. We aimed to assess the interchangeability rate (IR) of the breath-by-breath O2 uptake data calculated with the “Independent breath” (IND) and the “Expiration-only” (EXP) algorithms. Methods: Oxygen, carbon dioxide fractions, and ventilatory flow were recorded continuously over 26 min in 18 asthmatic and 20 well-matched healthy volunteers at rest, during cycling, and recovery; oxygen uptake (V’O2) was calculated with the two algorithms under comparison. Coefficients of variation (CVs) of all the steady-state condition were modeled as a function of the average V’O2 values and IR was calculated accordingly. Results: CVs were significantly greater in the asthmatic volunteers (F = 5.97, p < 0.05), being lower for IND compared to EXP (F > 7.04, p < 0.02). CVs decreased as a function of the reciprocal of the square root of the average V’O2. The IR, calculated on the basis of this relationship, was not significantly different in the two groups of volunteers (F = 0.77, p = 0.385); taking as reference method the IND, or EXP algorithms, the IR values were significantly different (F = 58.6, p < 0.001), amounting to 97.4 ± 2.2% or to 98.2 ± 1.7%, respectively. Conclusion: The relative noise of V’O2 was greater in the asthmatic volunteers compared to the healthy ones and was lower for IND compared to EXP. The interchangeability analysis suggested that IND might be a better substitute for EXP than the opposite.
DOI
10.1007/s00421-020-04374-w
WOS
WOS:000527481200001
Archivio
http://hdl.handle.net/11390/1181910
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85083505540
Diritti
metadata only access
Soggetti
  • Moderate intensity ex...

  • Normal distribution

  • Probability density f...

  • Standardized residual...

Scopus© citazioni
2
Data di acquisizione
Jun 2, 2022
Vedi dettagli
Web of Science© citazioni
2
Data di acquisizione
Mar 8, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback