Logo del repository
  1. Home
 
Opzioni

Relevance of b-values in evaluating liver fibrosis: a study in healthy and cirrhotic subjects using two single-shot spin-echo echo-planar diffusion-weighted sequences

GIROMETTI, Rossano
•
ESPOSITO, Gennaro
•
BAZZOCCHI, Massimo
altro
Soldano, F.
2008
  • journal article

Periodico
JOURNAL OF MAGNETIC RESONANCE IMAGING
Abstract
PURPOSE: To investigate the relevance of increasing b-values in evaluating liver fibrosis through the agreement of two diffusion-weighted (DW) sequences. MATERIALS AND METHODS: A total of 29 cirrhotic patients and 29 healthy volunteers were studied on a 1.5T system. Two single-shot spin-echo echo-planar sequences were acquired using sets of increasing b-values: 0, 150, 250, and 400 seconds/mm(2) (first sequence: DW1a) and 0, 150, 250, 400, 600, and 800 seconds/mm(2) (second sequence: DW2a). Apparent diffusion coefficients (ADCs) of the hepatic parenchyma were calculated on ADC maps. Noise-scaled single-point ADCs were calculated for each sequence from b = 400 seconds/mm(2). RESULTS: ADCs resulted significantly lower in cirrhotic patients compared to controls using both DW1a (mean 1.14 +/- 0.20 x 10(-3)mm(2)/second vs. 1.54 +/- 0.12 x 10(-3)mm(2)/second; P < 0.0001) and DW2a (mean 0.91 +/- 0.18 x 10(-3)mm(2)/second vs. 1.04 +/- 0.18 x 10(-3)mm(2)/second; P = 0.0089). DW1 and DW2, respectively significantly differed in diagnostic performance at receiver operating characteristic (ROC) curve analysis (P = 0.003), showing AUCs of 0.93 (sensitivity 89.7%, specificity 100%) and 0.73 (sensitivity 62.1%, specificity 79.3%), respectively. Noise-scaled single-point ADCs showed a progressive convergence to similar values in cirrhotic and healthy livers at b = 800 seconds/mm(2) (1.12 +/- 0.27 x 10(-3)mm(2)/second vs. 1.13 +/- 0.17 x 10(-3)mm(2)/second). CONCLUSION: A DW sequence is accurate in assessing liver fibrosis using intermediate (400 seconds/mm(2)) rather than high (800 seconds/mm(2)) maximum b-values, but after proper recalculation of ADCs the effects of perfusion rather than diffusion should be considered responsible for the higher accuracy at lower b-values.
DOI
10.1002/jmri.21461
WOS
WOS:000258387300017
Archivio
http://hdl.handle.net/11390/877613
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-49049083456
http://onlinelibrary.wiley.com/doi/10.1002/jmri.21461/pdf
Diritti
closed access
Soggetti
  • b-value

  • Diffusion-weighted MR...

  • Liver cirrhosi

  • Liver disease

  • Liver fibrosis

Scopus© citazioni
89
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
82
Data di acquisizione
Mar 26, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback