Logo del repository
  1. Home
 
Opzioni

Assessment of mobility deficit and treatment efficacy in adhesive capsulitis by measurement of kinematic parameters using IMU sensors

Ajcevic M.
•
Deodato M.
•
Murena L.
altro
Accardo A.
2020
  • conference object

Abstract
There is a growing research interest towards the use of wireless IMU sensors to assess disability, monitor progress and provide feedback to patients on range of motion and movement performance during upper body rehabilitation. The quality of movement in patients with adhesive capsulitis and relative treatment efficacy has not yet been studied using inertial and magnetic sensors. The aim of this study was to investigate the possibility to quantitatively evaluate capsulate-related deficit versus healthy controls and to assess treatment efficacy by measurement of shoulder kinematic parameters with ISEO protocol using inertial and magnetic measurement system technology. We enrolled 6 patients with adhesive capsulitis (AC) who underwent the experimental assessment by using a set of wireless IMU sensors at the baseline (T0) and after the 15 one- hour individual sessions of physiotherapy (T1). The range of motion in elevation, abduction and the scapulo-humeral rhythm kinematic parameters were extracted from measurements performed in enrolled AC patients and in 7 healthy controls. The results of this preliminary study showed that proposed approach based on measurement of shoulder kinematic parameters with ISEO protocol using IMU wireless sensors can be useful in mobility deficit assessment of patients with adhesive capsulitis, as well as for monitoring of treatment efficacy and its further personalization.
DOI
10.1109/MeMeA49120.2020.9137157
WOS
WOS:000612835700030
Archivio
http://hdl.handle.net/11368/2973489
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85088897820
https://ieeexplore.ieee.org/document/9137157
Diritti
closed access
license:copyright editore
FVG url
https://arts.units.it/request-item?handle=11368/2973489
Soggetti
  • adhesive capsuliti

  • IMU sensor

  • kinematic parameter

  • shoulder

  • wearable

Scopus© citazioni
0
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
0
Data di acquisizione
Mar 9, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback