Logo del repository
  1. Home
 
Opzioni

Lung Volume and Ventilation Distribution After Bariatric Surgery-High-Flow Nasal Cannula Versus CPAP

Lena, Enrico
•
Comuzzi, Lucia
•
AjÄ eviÄ , Milos
altro
Lucangelo, Umberto
2024
  • journal article

Periodico
RESPIRATORY CARE
Abstract
Background: Patients with obesity are at increased risk of postoperative pulmonary complications. CPAP has been used successfully to prevent and treat acute respiratory failure, but in many clinical scenarios, high-flow nasal cannula (HFNC) therapy is emerging as a possible alternative. We aimed to compare HFNC and CPAP in a sequential study measuring their effects on gas exchange, lung volumes, and gas distribution within the lungs measured through electrical impedance tomography (EIT). Methods: We enrolled 15 subjects undergoing laparoscopic bariatric surgery. Postoperatively they underwent the following oxygen therapy protocol (10 min/step): baseline air-entrainment mask, HFNC at increasing (40, 60, 80, and 100 L/min) and decreasing flows (80, 60, and 40 L/min), washout air-entrainment mask and CPAP (10 cm H2O). Primary outcome was the change in end-expiratory lung impedance (ΔEELI) measured by EIT data processing. Secondary outcomes were changes of global inhomogeneity (GI) index and tidal impedance variation (TIV) measured by EIT, arterial oxygenation, carbon dioxide content, pH, respiratory frequency, and subject's comfort. Results: Thirteen subjects completed the study. Compared to baseline, ΔEELI was higher during 10 cm H2O CPAP (P = .001) and HFNC 100 L/min (P = .02), as well as during decreasing flows HFNC 80, 60, and 40 L/min (P = .008, .004, and .02, respectively). GI index was lower during HFNC 100 compared to HFNC 60increasing (P = .044), HFNC 60decreasing (P = .02) HFNC 40decreasing (P = .01), and during 10 cm H2O CPAP compared to washout period (P = .01) and HFNC 40decreasing (P = .03). TIV was higher during 10 cm H2O CPAP compared to baseline (P = .008). Compared to baseline, breathing frequency was lower at HFNC 60increasing, HFNC 100, and HFNC 80decreasing (P = .01, .02, and .03, respectively). No differences were detected regarding arterial oxygenation, carbon dioxide content, pH, and subject's comfort. Conclusions: HFNC at a flow of 100 L/min induced postoperative pulmonary recruitment in bariatric subjects, with no significant differences compared to 10 cm H2O CPAP in terms of lung recruitment and ventilation distribution.
DOI
10.4187/respcare.11356
WOS
WOS:001302500800012
Archivio
https://hdl.handle.net/11368/3081499
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85199812403
https://rc.rcjournal.com/content/69/8/990.short
Diritti
closed access
license:copyright editore
license uri:iris.pri02
FVG url
https://arts.units.it/request-item?handle=11368/3081499
Soggetti
  • CPAP

  • bariatric surgery

  • electrical impedance ...

  • high-flow nasal cannu...

  • lung recruitment

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback