Logo del repository
  1. Home
 
Opzioni

Prognostic value of implantable defibrillator–computed respiratory disturbance index: The DASAP-HF study

Boriani G.
•
Pisano E. C. L.
•
Pieragnoli P.
altro
D'Onofrio A.
2021
  • journal article

Periodico
HEART RHYTHM
Abstract
Background: Sleep apnea, as measured by polysomnography, is associated with adverse outcomes in heart failure. The DASAP-HF (Diagnosis and Treatment of Sleep Apnea in Patient With Heart Failure) study previously demonstrated that the respiratory disturbance index (RDI) computed by the ApneaScan algorithm (Boston Scientific) accurately identifies severe sleep apnea in implantable cardioverter-defibrillator (ICD) patients. Objective: The purpose of the long-term study phase was to assess the incidence of clinical events after 24 months and investigate the association with RDI values. Methods: Patients with left ventricular ejection fraction ≤35% implanted with an ICD were enrolled and followed-up for 24 months. The RDI calculated at 1 month after implantation was used to stratify patients (below or above 30 episodes/h). The endpoints were all-cause death and a combination of all-cause death or cardiovascular hospitalization. Results: Of the 265 enrolled patients, 224 had usable RDI values. Severe sleep apnea (RDI ≥30 episodes/h) was diagnosed in 115 patients (51%). These patients were more frequently male (84% vs 72%; P = .030) and had higher creatinine levels. During median follow-up of 25 months, 19 patients (8%) died. Cardiovascular hospitalizations were reported in 19 patients (8%). The risk of all-cause death was higher in patients with RDI ≥30 episodes/h (hazard ratio [HR] 3.33; 95% confidence interval [CI] 1.35–8.21; P = .023), as well as the risk of all-cause death or cardiovascular hospitalization (HR 1.94; 95% CI 1.01–3.76; P = .048). At multivariate analysis, independent predictors of death were RDI ≥30 episodes/h (HR 4.02; 95% CI 1.16–13.97; P = .029) and creatinine levels (HR 2.36; 95% CI 1.26–4.42; P = .008). Conclusion: In heart failure patients implanted with an ICD, higher RDI values are associated with death and cardiovascular hospitalizations. Device-detected severe sleep apnea independently predicts death.
DOI
10.1016/j.hrthm.2020.10.019
WOS
WOS:000634894400007
Archivio
http://hdl.handle.net/11368/2992317
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85101206860
https://www.sciencedirect.com/science/article/abs/pii/S1547527120310304?via=ihub
Diritti
closed access
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2992317
Soggetti
  • Heart failure

  • Implantable cardiover...

  • Prognosi

  • Respiratory disturban...

  • Sleep apnea

Web of Science© citazioni
2
Data di acquisizione
Mar 23, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback