Logo del repository
  1. Home
 
Opzioni

Vessel specific coronary artery calcium scoring: an automatic system

Shahzad R
•
van Walsum T
•
Schaap M
altro
Niessen WJ
2013
  • journal article

Periodico
ACADEMIC RADIOLOGY
Abstract
RATIONALE AND OBJECTIVES: The aim of this study was to automatically detect and quantify calcium lesions for the whole heart as well as per coronary artery on non-contrast-enhanced cardiac computed tomographic images. MATERIALS AND METHODS: Imaging data from 366 patients were randomly selected from patients who underwent computed tomographic calcium scoring assessments between July 2004 and May 2009 at Erasmum MC, Rotterdam. These data included data sets with 1.5-mm and 3.0-mm slice spacing reconstructions and were acquired using four different scanners. The scores of manual observers, who annotated the data using commercially available software, served as ground truth. An automatic method for detecting and quantifying calcifications for each of the four main coronary arteries and the whole heart was trained on 209 data sets and tested on 157 data sets. Statistical testing included determining Pearson's correlation coefficients and Bland-Altman analysis to compare performance between the system and ground truth. Wilcoxon's signed-rank test was used to compare the interobserver variability to the system's performance. RESULTS: Automatic detection of calcified objects was achieved with sensitivity of 81.2% per calcified object in the 1.5-mm data set and sensitivity of 86.6% per calcified object in the 3.0-mm data set. The system made an average of 2.5 errors per patient in the 1.5-mm data set and 2.2 errors in the 3.0-mm data set. Pearson's correlation coefficients of 0.97 (P < .001) for both 1.5-mm and 3.0-mm scans with respect to the calcium volume score of the whole heart were found. The average R values over Agatston, mass, and volume scores for each of the arteries (left circumflex coronary artery, right coronary artery, and left main and left anterior descending coronary arteries) were 0.93, 0.96, and 0.99, respectively, for the 1.5-mm scans. Similarly, for 3.0-mm scans, R values were 0.94, 0.94, and 0.99, respectively. Risk category assignment was correct in 95% and 89% of the data sets in the 1.5-mm and 3-mm scans. CONCLUSIONS: An automatic vessel-specific coronary artery calcium scoring system was developed, and its feasibility for calcium scoring in individual vessels and risk category classification has been demonstrated.
Archivio
http://hdl.handle.net/11368/2760788
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84870866172
Diritti
metadata only access
Soggetti
  • non-contrast-enhanced...

  • coronary calcium scor...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback