Logo del repository
  1. Home
 
Opzioni

Variability of cut-off values for the detection of lupus anticoagulants: Results of an international multicenter multiplatform study

Tripodi, A
•
Chantarangkul, V.
•
Cini, M.
altro
GIACOMELLO, Roberta
2017
  • journal article

Periodico
JOURNAL OF THROMBOSIS AND HAEMOSTASIS
Abstract
Abstract Essentials Between-lab variations of cut-off values in lupus anticoagulant detection are unknown. Cut-off values were calculated in 11 labs each testing plasma from 120 donors with 3 platforms. Major variation was observed even within the same platform. Cut-off values determined in different labs are not interchangeable. SUMMARY: Background Cut-off values for interpretation of lupus anticoagulant (LA) detection are poorly investigated. Aims (i) To assess whether results from healthy donors were normally distributed and (ii) the between-laboratories differences in cut-off values for screening, mixing and LA confirmation when calculated as 99th or 95th centiles, and (iii) to assess their impact on the detection rate for LA. Methods Each of 11 laboratories using one of the three widely used commercial platforms for LA detection was asked to collect plasmas from 120 healthy donors and to perform screening, mixing and LA confirmation with two methods (activated partial thromboplastin time [APTT] and dilute Russell viper venom [dRVV]). A common set of LA-positive or LA-negative freeze-dried plasmas was used to assess the LA detection rate. Results were centralized (Milano) for statistical analysis. Results and conclusions (i) Clotting times or ratios for healthy subjects were not normally distributed in the majority of cases. The take-home message is that cut-off values should be determined preferably by the non-parametric method based on centiles. (ii) There were relatively large inter-laboratory cut-off variations even within the same platform and the variability was marginally attenuated when results were expressed as ratios (test-to-normal pooled plasma). The take-home message is that cut-off values should be determined locally. (iii) There were differences between cut-off values calculated as 99th or 95th centiles that translate into a different LA detection rate (the lower the centile the greater the detection rate). The take-home message is that cut-off values determined as the 95th centile allow a better LA detection rate.
DOI
10.1111/jth.13678
WOS
WOS:000402865700016
Archivio
http://hdl.handle.net/11390/1111761
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85018855801
Diritti
metadata only access
Soggetti
  • Activated partial thr...

  • Antiphospholipid synd...

  • Dilute Russell viper ...

  • Screening

  • Standardization

  • Hematology

Scopus© citazioni
22
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
24
Data di acquisizione
Mar 27, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback