Risk assessment of vascular disorders by a supplementary hand–arm vascular weighting of hand-transmitted vibration

Massimo Bovenzi
•
Iole Pinto
•
Francesco Picciolo
2019
  • journal article

Periodico
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH
Abstract
PURPOSE: To provide an updated epidemiological validation for a supplementary method for assessing the risk of vascular disorders from hand-transmitted vibration. METHODS: The occurrence of vibration-induced white finger (VWF) in the vibration-exposed workers of the Italian cohort of the EU VIBRISKS study was related to measures of daily vibration exposure expressed in terms of r.m.s. acceleration magnitude normalised to an 8-h day, frequency weighted according to either the frequency weighting Wh defined in international standard ISO 5349-1:2001 [Ah(8) in ms- 2] or the hand-arm vascular frequency weighting Wp proposed in the ISO technical report (TR) 18570:2017 [Ap(8) in ms- 2]. To estimate a threshold value for vascular hand-arm vibration risk, the Wp-weighted vibration exposure value Ep,d (in ms- 1.5) was calculated according to the ISO/TR document. The difference in the predictions of VWF between the exposure measures calculated with the frequency weightings Wh or Wp was investigated by means of logistic modelling. RESULTS: Measures of daily vibration exposure constructed with the frequency weighting Wp [Ap(8) and Ep,d], which gives more importance to intermediate- and high-frequency vibration, were better predictors of the occurrence of VWF in the vibration-exposed workers than the metric derived from the conventional ISO frequency weighting Wh [Ah(8)]. There was some epidemiological evidence for a threshold value of Ep,d for the onset of VWF in the vibration-exposed workers. CONCLUSIONS: Measures of daily vibration exposure evaluated with the vascular weighting Wp performed better for the predictions of VWF than those obtained with the frequency weighting Wh recommended in ISO 5349-1.
DOI
10.1007/s00420-018-1363-y
WOS
WOS:000455144300012
Archivio
http://hdl.handle.net/11368/2929700
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85054301021
https://link.springer.com/article/10.1007%2Fs00420-018-1363-y
Diritti
closed access
license:copyright editore
FVG url
https://arts.units.it/request-item?handle=11368/2929700
Soggetti
  • Frequency weighting

  • Epidemiology

  • Hand-transmitted vibr...

  • Vascular disorders

Scopus© citazioni
6
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
7
Data di acquisizione
Mar 24, 2024
Visualizzazioni
1
Data di acquisizione
Jun 8, 2022
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback