Logo del repository
  1. Home
 
Opzioni

A Rapid High-Performance Liquid Chromatography Method to Measure Linezolid and Daptomycin Concentrations in Human Plasma

Polillo M
•
Tascini C
•
Lastella M
altro
Di Paolo A
2010
  • journal article

Periodico
THERAPEUTIC DRUG MONITORING
Abstract
Daptomycin and linezolid, recently introduced to treat severe Gram-positive infections, are effective against multidrug-resistant Gram-positive microorganisms such as methicillin-resistant Staphylococcus aureus, methicillin-resistant Staphylococcus epidermidis, and vancomycin-resistant Enterococci bacteria that are less sensitive or frankly resistant, including methicillin-resistant S. aureus. However, alteration of their plasma profile has been described in some patients and this may be associated with toxicities or selection of resistant strains. The measurement of plasma concentrations of both drugs may allow the identification of those subjects at major risk of adverse events. Therefore, a rapid and sensitive high-performance liquid chromatography method for the analysis of daptomycin and linezolid was developed and applied in clinical settings. Drugs were extracted from plasma by adding methanol and, after centrifugation, clear supernatants were injected into the high-performance liquid chromatography system. Isocratic elution (1.5 mL/min) was performed using a mobile phase consisting of ammonium phosphate buffer 40 mM, pH 4.0, acetonitrile (70:30, vol/vol) through a BDS C(8) Hypersil stationary phase (250 x 4.6 mm, 5 mu m); ultraviolet detection was used at 214 nm. Linezolid and daptomycin eluted within 20 minutes from the injection, and mean recoveries ranged between 95.4% and 112.1%, respectively. The method was linear (coefficient of linearity, 0.998-0.999) over the full range of concentrations assayed, from 0.78125 mg/L (limit of quantitation) to 100 mg/L for both drugs. The Sy.x values were equal to 0.25 +/- 0.10 and 0.29 +/- 0.18 mg/L for daptomycin and linezolid, respectively. Precision values were lower than 20% over the entire range of calibration standard, and accuracy was within the range of 80% to 120% for all concentrations. The present method proved to be sensitive and specific to measure daptomycin and linezolid plasma concentrations in patients affected by severe Gram-positive infections, allowing therapeutic drug monitoring in those patients at major risk of severe adverse events.
DOI
10.1097/FTD.0b013e3181d3f5cb
WOS
WOS:000276165300013
Archivio
http://hdl.handle.net/11390/1199050
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-77950225669
Diritti
metadata only access
Scopus© citazioni
32
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
28
Data di acquisizione
Mar 16, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback