The high voltage system with pressure and temperature corrections for the novel MPGD-based photon detectors of COMPASS RICH-1

Agarwala J.
•
Bari M.
•
Bradamante F.
altro
Zhao Y. X.
2019
  • journal article

Periodico
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT
Abstract
The novel MPGD-based photon detectors of COMPASS RICH-1 consist of large-size hybrid MPGDs with multi-layer architecture including two layers of Thick-GEMs and a bulk resistive MicroMegas. The top surface of the first THGEM is coated with a CsI film which also acts as photo-cathode. These detectors have been successfully in operation at COMPASS since 2016. Concerning bias-voltage supply, the Thick-GEMs are segmented in order to reduce the energy released in case of occasional discharges, while the MicroMegas anode is segmented into pads individually biased with positive voltage while the micromesh is grounded. In total, there are about ten different electrode types and more than 20000 electrodes supplied by more than 100 HV channels, where appropriate correlations among the applied voltages are required for the correct operation of the detectors. Therefore, a robust control system is mandatory, implemented by a custom designed software package, while commercial power supply units are used. This sophisticated control system allows to protect the detectors against errors by the operator, to monitor and log voltages and currents at 1 Hz rate, and automatically react to detector misbehavior. In addition, a voltage compensation system has been developed to automatically adjust the biasing voltage according to environmental pressure and temperature variations, to achieve constant gain over time. This development answers to a more general need. In fact, voltage compensation is always a requirement for the stability of gaseous detectors and its need is enhanced in multi-layer ones. In this paper, the HV system and its performance are described in details, as well as the stability of the novel MPGD-based photon detectors during the physics data taking at COMPASS.
DOI
10.1016/j.nima.2019.162378
WOS
WOS:000480338100010
Archivio
http://hdl.handle.net/11368/2948702
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85069491616
https://www.sciencedirect.com/science/article/pii/S0168900219309672?via=ihub
Diritti
closed access
license:copyright editore
FVG url
https://arts.units.it/request-item?handle=11368/2948702
Soggetti
  • COMPASS

  • Gain

  • HV system

  • MPGD

  • Pressure and temperat...

  • RICH-1

Scopus© citazioni
4
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
4
Data di acquisizione
Mar 16, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback