Logo del repository
  1. Home
 
Opzioni

A case study of modern heritage building: Base isolation seismic retrofit for preservation of its architectural distinguishing features

Terenzi G.
•
Fuso E.
•
Sorace S.
•
Costoli I.
2020
  • conference object

Periodico
IOP CONFERENCE SERIES: MATERIALS SCIENCE AND ENGINEERING
Abstract
Several Italian buildings designed by eminent architects and structural engineers in the second half of the 20th century are now included in modern heritage listings. At the same time, as they were designed before the issue of coordinate national Technical Standards, often require important structural rehabilitation interventions. One of the most representative case studies of that period in Florence, i.e. the building now housing the Automobile Club Headquarter and a B&B Hotel, is examined in this paper. A seismic assessment analysis carried out on the structure highlighted strength deficiencies in several members and potentially severe pounding conditions between the two constituting wings of the building, separated by a narrow technical gap. In order to improve the seismic performance without altering the architectural appearance of the building, characterized by large windows in the façades, free internal spaces and elegant proportions of the main structural members, a base isolation retrofit hypothesis is proposed. A substantial seismic improvement is obtained in rehabilitated conditions, as assessed by the achievement of safe stress states for all members up to the basic design normative earthquake level, as well as of maximum relative lateral displacements of the two wings constrained below the technical gap width.
DOI
10.1088/1757-899X/960/3/032056
WOS
WOS:000646533100165
Archivio
http://hdl.handle.net/11390/1195681
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85098009730
Diritti
open access
Web of Science© citazioni
0
Data di acquisizione
Mar 15, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback