Logo del repository
  1. Home
 
Opzioni

Entrance and temperature dependent viscosity effects on laminar forced convection in straight ducts with uniform wall heat flux

DEL GIUDICE, Stefano
•
SAVINO, Stefano
•
NONINO, Carlo
2011
  • journal article

Periodico
JOURNAL OF HEAT TRANSFER
Abstract
In this paper a parametric investigation is carried out on the effects of temperature dependent viscosity in simultaneously, i.e., hydro-dynamically and thermally, developing laminar flows of liquids in straight ducts of constant cross sections. Uniform heat flux boundary conditions are imposed on the heated walls of the ducts. Different cross-sectional geometries are considered, corresponding to both axisymmetric (circular and concentric annular) and three-dimensional (rectangular and trapezoidal) ducts. Viscosity is assumed to vary with temperature according to an exponential relation, while the other fluid properties are held constant. A finite element procedure is employed for the solution of the parabolized momentum and energy equations. Computed axial distributions of the local Nusselt number and of the apparent Fanning friction factor are presented for different values of the Pearson and Prandtl numbers. Numerical results confirm that, in the laminar forced convection in the entrance region of straight ducts, the effects of temperature dependent viscosity cannot be neglected in a wide range of operative conditions. Correlations are also provided for the local Nusselt number and the apparent Fanning friction factor in simultaneously developing flows in ducts of different cross sections.
DOI
10.1115/1.4004171
WOS
WOS:000294211000009
Archivio
http://hdl.handle.net/11390/878177
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-80051863027
Diritti
closed access
Scopus© citazioni
8
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
9
Data di acquisizione
Mar 9, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback