Logo del repository
  1. Home
 
Opzioni

Hitting the refractive target in corneal endothelial transplantation triple procedures: A systematic review

Giglio, Rosa
•
Vinciguerra, Alex Lucia
•
Grotto, Alberto
altro
Tognetto, Daniele
2024
  • journal article

Periodico
SURVEY OF OPHTHALMOLOGY
Abstract
In phakic patients Descemet stripping automated endothelial keratoplasty (DSAEK) or Descemet membrane endothelial keratoplasty (DMEK) are frequently combined with phacoemulsification and intraocular lens (IOL) implantation (triple procedure). This surgery might cause a refractive shift difficult to predict. Early DMEK and DSAEK results have shown a tendency toward a hyperopic shift. Myopic postoperative refraction is typically intended to correct this postoperative refractive defect and to bring all eyes as close to emmetropia as possible. We sought to understand the mechanism underlying the hyperopization and to identify predictive factors for poorer refractive outcomes, the most suitable target refraction and IOL calculation methods in patients undergoing combined cataract extraction and lamellar endothelial corneal transplantation (DSAEK or DMEK) for endothelial dysfunctions. Of the 407 articles analyzed, only 18 were included in the analysis. A myopic target between -0.50 D and -0.75 was the most common (up to -1.50 for DSAEK triple procedures), even though no optimum target was found. Hyperopic surprises appeared more frequently in corneas that were flatter in the center than in the periphery (oblate posterior profile). Among the numerous IOL calculation formulas, there was no apparent preference.
DOI
10.1016/j.survophthal.2024.01.003
WOS
WOS:001234168400001
Archivio
https://hdl.handle.net/11368/3073645
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85186318188
https://www.sciencedirect.com/science/article/pii/S0039625724000031?via=ihub
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/3073645/3/1-s2.0-S0039625724000031-main.pdf
Soggetti
  • Cataract surgery

  • Descemet’s membrane e...

  • Descemet’s stripping ...

  • IOL power calculation...

  • Refractive error

  • Triple procedure

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback