Logo del repository
  1. Home
 
Opzioni

Efficacy of functional hemodynamic parameters in predicting fluid responsiveness with pulse power analysis in surgical patients.

Cecconi M
•
Monti G
•
Hamilton MA
altro
DELLA ROCCA, Giorgio
2012
  • journal article

Periodico
MINERVA ANESTESIOLOGICA
Abstract
Background. In this study we quantify the ability of dynamic cardiovascular parameters measured by the Pulse- COTM algorithm of the LiDCOTMplus monitor to predict the response to a fluid challenge in post-operative patients. Methods. Surgical patients, admitted to the Intensive Care Unit from the operating theatre were monitored with the LiDCOTMplus system. A number of static and dynamic cardiovascular measurements were recorded before and after a fluid challenge. Receiver Operator Characteristic (ROC) curve analysis was used to identify the baseline values, with optimum sensitivity and specificity, to predict responsiveness to a fluid challenge. Results. Thirty-one patients were enrolled, and received protocol-based fluid challenges. Twelve (38%) responded by demonstrating an increase in stroke volume of >15%. Heart rate (HR) and central venous pressure (CVP) were not statistically different between responders and non-responders. Mean arterial pressure (mAP), systolic pressure vari- ation (SPV), pulse pressure variation (PPV) and stroke volume variation (SVV) were statistically different between responders and non-responders. Parameters with a ROC area under the curve (AUC) significantly >0.5 included SPV 0.70 (0.52-0.88) P=0.046, PPV 0.87 (0.76-0.99) P<0.0002 and SVV 0.84 (0.71-0.96) P=0.0005. The best cut-off values (sensitivity and specificity) to predict fluid were SPV >9 mmHg (73%, 76%), PPV >13% (83%, 74%) and SVV >12.5% (75%, 83%). ROC analysis did not show the AUC to be significantly >0.5 for HR, mAP and CVP Conclusion. Dynamic indices measured by PulseCOTM (LiDCO) have a high sensitivity and specificity in predicting fluid responsiveness in sedated and mechanically ventilated patients. A cut-off value for PPV of 13% is the most sensitive and specific indicator of fluid responsiveness.
WOS
WOS:000303962000004
Archivio
http://hdl.handle.net/11390/866861
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84860267732
Diritti
closed access
Soggetti
  • body fluid

  • central venous pressu...

  • heart rate

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback