Logo del repository
  1. Home
 
Opzioni

Primary stability of short implants inserted using piezoelectric or drilling systems: An in vitro comparison

Stacchi C.
•
De Biasi M.
•
Torelli L.
altro
Angerame D.
2019
  • journal article

Periodico
JOURNAL OF ORAL IMPLANTOLOGY
Abstract
The primary objective of the present in vitro study was to evaluate the influence of implant site preparation technique (drills vs ultrasonic instrumentation) on the primary stability of short dental implants with two different designs inserted in simulated low-quality cancellous bone. Eighty implant sites were prepared in custom-made solid rigid polyurethane blocks with two different low cancellous bone densities (5 or 15 pounds per cubic foot [PCF]), equally distributed between piezoelectric (Surgysonic Moto, Esacrom, Italy) and conventional drilling techniques. Two short implant systems (Prama and Syra, Sweden & Martina) were tested by inserting 40 fixtures of each system (both 6.0 mm length and 5.0 mm diameter), divided in the four subgroups (drills/5 PCF density; drills/15 PCF density; piezo/5 PCF density; piezo/15 PCF density). Insertion torque (Ncm), implant stability quotient values, removal torque (Ncm), and surgical time were recorded. Data were analyzed by 3-way ANOVA and Scheffé’s test (a 1⁄4 0.05). With slight variations among the considered dependent variables, overall high primary implant stability was observed across all subgroups. Piezoelectric instrumentation allowed for comparable or slightly superior primary stability in comparison with the drilling procedures in both implant systems. The Prama implants group showed the highest mean reverse torque and Syra implants the highest implant stability quotient values. Piezoelectric implant site preparation took prolonged operative time compared to conventional preparation with drills; among the drilling procedures, Syra system required fewer surgical steps and shorter operative time.
DOI
10.1563/aaid-joi-18-00157
WOS
WOS:000486427700002
Archivio
http://hdl.handle.net/11368/2959153
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85072375316
https://www.joionline.org/doi/pdf/10.1563/aaid-joi-18-00157
Diritti
closed access
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2959153
Soggetti
  • Implant site preparat...

  • Piezoelectric surgery...

  • Polyurethane foam blo...

  • Posterior maxilla

  • Short implant

  • Bone Density

  • Polyurethane

  • Torque

  • Dental Implantation, ...

  • Dental Implants

Web of Science© citazioni
8
Data di acquisizione
Mar 15, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback