Amperometric Sniffer for Volatile Amines Based on Paper-Supported Room Temperature Ionic Liquids Enabling Rapid Assessment of Fish Spoilage

Toniolo, Rosanna
•
Dossi, Nicolo
•
Svigelj, Rossella
altro
Bontempelli, Gino
2014
  • journal article

Periodico
ELECTROANALYSIS
Abstract
A gas sensors based on a room temperature ionic liquid (RTIL) supported on paper is proposed as amperometric sniffer for monitoring volatile amines (VAs) released from fish samples, in order to gain indication of their state of turning spoiled. It was used as a paper electrochemical detector (PED) for a flow injection system in which controlled headspace volumes in equilibrium with ice-stored fish samples were directly injected. The performance of this RTIL-PED sensor was preliminarily tested on synthetic samples of trimethylamine (TMA), dimethylamine (DMA), methylamine (MA) and ammonia (i.e. the main species responsible for the typical flavor of spoiled fish), thus verifying that only TMA, DMA and MA can be detected because NH3 oxidation occurred beyond the solvent discharge. This notwithstanding, detection of the sole TMA, DMA and MA as a whole turned out to be well suited for the rapid assessment of fish spoilage, since during storage the release enhancement for these amines is largely predominant over that of NH3. Repeatable (8% RSD) sharp peaks were detected for all amines above over a wide range (5-1000 nmol) and a detection limit of a little more than 3 nmol was inferred for a signal-to-noise ratio of 3. This approach was applied to the detection of VAs released from real fish samples (sardines), in parallel to the determination of their total volatile basic nitrogen (TVBN), which is a conventional indicator frequently adopted for the chemical quality assessment of fish. A substantially satisfactory agreement was found by comparing the data achieved by these two approaches. © 2014 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOI
10.1002/elan.201400276
WOS
WOS:000343926700014
Archivio
http://hdl.handle.net/11390/1050587
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84924968909
http://onlinelibrary.wiley.com/doi/10.1002/elan.201400276/epdf
Diritti
closed access
Soggetti
  • Amperometric sniffer

  • Fish spoilage assessm...

  • Flow injection analys...

  • Paper based electroch...

  • Room temperature ioni...

  • RTIL-paper-based sens...

  • Volatile amines (VAs)...

Scopus© citazioni
14
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
15
Data di acquisizione
Mar 28, 2024
Visualizzazioni
3
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback