Logo del repository
  1. Home
 
Opzioni

Do rebreathing manoeuvres for non-invasive measurement of cardiac output during maximum exercise test alter the main cardiopulmonary parameters?

Vignati C.
•
Morosin M.
•
Fusini L.
altro
Agostoni P.
2019
  • journal article

Periodico
EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY
Abstract
Background: Inert gas rebreathing has been recently described as an emergent reliable non-invasive method for cardiac output determination during exercise, allowing a relevant improvement of cardiopulmonary exercise test clinical relevance. For cardiac output measurements by inert gas rebreathing, specific respiratory manoeuvres are needed which might affect pivotal cardiopulmonary exercise test parameters, such as exercise tolerance, oxygen uptake and ventilation vs carbon dioxide output (VE/VCO2) relationship slope. Method: We retrospectively analysed cardiopulmonary exercise testing of 181 heart failure patients who underwent both cardiopulmonary exercise testing and cardiopulmonary exercise test+cardiac output within two months (average 16 ± 15 days). All patients were in stable clinical conditions (New York Heart Association I–III) and on optimal medical therapy. Results: The majority of patients were in New York Heart Association Class I and II (78.8%), with a mean left ventricular ejection fraction of 31 ± 10%. No difference was found between the two tests in oxygen uptake at peak exercise (1101 (interquartile range 870–1418) ml/min at cardiopulmonary exercise test vs 1103 (844–1389) at cardiopulmonary exercise test-cardiac output) and at anaerobic threshold. However, anaerobic threshold and peak heart rate, peak workload (75 (58–101) watts and 64 (42–90), p < 0.01) and carbon dioxide output were significantly higher at cardiopulmonary exercise testing than at cardiopulmonary exercise test+cardiac output, whereas VE/VCO2 slope was higher at cardiopulmonary exercise test+cardiac output (30 (27–35) vs 33 (28–37), p < 0.01). Conclusion: The similar anaerobic threshold and peak oxygen uptake in the two tests with a lower peak workload and higher VE/VCO2 slope at cardiopulmonary exercise test+cardiac output suggest a higher respiratory work and consequent demand for respiratory muscle blood flow secondary to the ventilatory manoeuvres. Accordingly, VE/VCO2 slope and peak workload must be evaluated with caution during cardiopulmonary exercise test+cardiac output.
DOI
10.1177/2047487319845967
WOS
WOS:000487017600009
Archivio
http://hdl.handle.net/11368/2962752
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85065251140
https://journals.sagepub.com/doi/full/10.1177/2047487319845967
Diritti
open access
license:digital rights management non definito
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2962752
Soggetti
  • Cardiac output

  • cardiopulmonary exerc...

  • inert gas rebreathing...

Scopus© citazioni
5
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
7
Data di acquisizione
Feb 6, 2024
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback