Analysis, testing, design and construction of a base isolated/supplementally damped building

SORACE, Stefano
•
Terenzi, Gloria
2008
  • conference object

Abstract
The first actual application to a demonstrative strategic building of a special base isolation/supplemental damping system, where fluid viscous spring-dampers are coupled to steel-Teflon sliders, is presented in this paper. The results of a testing campaign aimed at assessing the interference of the dissipative actions of the two component devices, as a final step of the research studies previously developed by the authors on this technology, are summed up. The design and performance evaluation analyses carried out on the building are then discussed. Highlights of the construction works and technical installation details are finally illustrated.
Archivio
http://hdl.handle.net/11390/855295
Diritti
closed access
Soggetti
  • Advanced seismic prot...

  • Base isolation

  • Damping

Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback