Logo del repository
  1. Home
 
Opzioni

Cardiac resynchronization therapy by multipoint pacing improves response of left ventricular mechanics and fluid dynamics: a three-dimensional and particle image velocimetry echo study

Siciliano, Mariachiara
•
Migliore, Federico
•
Badano, Luigi
altro
Muraru, Denisa
2016
  • journal article

Periodico
EUROPACE
Abstract
Aims: To characterize the effect of multipoint pacing (MPP) compared to biventricular pacing (BiV) on left ventricle (LV) mechanics and intraventricular fluid dynamics by three-dimensional echocardiography (3DE) and echocardiographic particle imaging velocimetry (Echo-PIV). Methods and results: In 11 consecutive patients [8 men; median age 65 years (57–75)] receiving cardiac resynchronization therapy (CRT) with a quadripolar LV lead (Quartet,St.Jude Medical,Inc.), 3DE and Echo-PIV data were collected for each pacing configuration (CRT-OFF, BiV, and MPP) at follow-up after 6 months. 3DE data included LV volumes, LV ejection fraction (LVEF), strain, and systolic dyssynchrony index (SDI). Echo-PIV was used to evaluate the directional distribution of global blood flow momentum, ranging from zero, when flow force is predominantly along the base–apex direction, up to 90 when it becomes transversal. MPP resulted in significant reduction in end-diastolic and end-systolic volumes compared with both CRT-OFF (P 1⁄4 0.02; P 1⁄4 0.008, respectively) and BiV (P 1⁄4 0.04; P 1⁄4 0.03, respectively). LVEF and cardiac output were significant superior in MPP compared with CRT-OFF, but similar between MPP and BiV. Statistical significant differences when comparing global longitudinal and circumferential strain and SDI with MPP vs. CRT-OFF were observed (P 1⁄4 0.008; P 1⁄4 0.008; P 1⁄4 0.01, respectively). There was also a trend towards improvement in strain between BiV and MPP that did not reach statistical significance. MPP reflected into a significant reduction of the deviation of global blood flow momentum compared with both CRTOFF and BiV (P 1⁄4 0.002) indicating a systematic increase of longitudinal alignment from the base–apex orientation of the haemodynamic forces.Conclusion. These preliminary results suggest that MPP resulted in significant improvement of LV mechanics and fluid dynamics compared with BiV. However, larger studies are needed to confirm this hypothesis
DOI
10.1093/europace/euw331
WOS
WOS:000414367100015
Archivio
http://hdl.handle.net/11368/2892400
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85034853226
Diritti
closed access
FVG url
https://arts.units.it/request-item?handle=11368/2892400
Soggetti
  • 3D echocardiography

  • Cardiac fluid mechani...

  • Cardiac resynchroniza...

  • Heart failure

  • Multipoint pacing

  • Particle image veloci...

Scopus© citazioni
25
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
23
Data di acquisizione
Mar 13, 2024
Visualizzazioni
3
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback