Logo del repository
  1. Home
 
Opzioni

Accuracy of right atrial pressure estimation using a multi-parameter approach derived from inferior vena cava semi-automated edge-tracking echocardiography: a pilot study in patients with cardiovascular disorders

Albani S.
•
Pinamonti B.
•
Giovinazzo T.
altro
Mesin L.
2020
  • journal article

Periodico
THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING
Abstract
The echocardiographic estimation of right atrial pressure (RAP) is based on the size and inspiratory collapse of the inferior vena cava (IVC). However, this method has proven to have limits of reliability. The aim of this study is to assess feasibility and accuracy of a new semi-automated approach to estimate RAP. Standard acquired echocardiographic images were processed with a semi-automated technique. Indexes related to the collapsibility of the vessel during inspiration (Caval Index, CI) and new indexes of pulsatility, obtained considering only the stimulation due to either respiration (Respiratory Caval Index, RCI) or heartbeats (Cardiac Caval Index, CCI) were derived. Binary Tree Models (BTM) were then developed to estimate either 3 or 5 RAP classes (BTM3 and BTM5) using indexes estimated by the semi-automated technique. These BTMs were compared with two standard estimation (SE) echocardiographic methods, indicated as A and B, distinguishing among 3 and 5 RAP classes, respectively. Direct RAP measurements obtained during a right heart catheterization (RHC) were used as reference. 62 consecutive ‘all-comers’ patients that had a RHC were enrolled; 13 patients were excluded for technical reasons. Therefore 49 patients were included in this study (mean age 62.2 ± 15.2 years, 75.5% pulmonary hypertension, 34.7% severe left ventricular dysfunction and 51% right ventricular dysfunction). The SE methods showed poor accuracy for RAP estimation (method A: misclassification error, ME = 51%, R2 = 0.22; method B: ME = 69%, R2 = 0.26). Instead, the new semi-automated methods BTM3 and BTM5 have higher accuracy (ME = 14%, R2 = 0.47 and ME = 22%, R2 = 0.61, respectively). In conclusion, a multi-parametric approach using IVC indexes extracted by the semi-automated approach is a promising tool for a more accurate estimation of RAP.
DOI
10.1007/s10554-020-01814-8
WOS
WOS:000520989600002
Archivio
http://hdl.handle.net/11368/2962745
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85082061821
https://link.springer.com/article/10.1007/s10554-020-01814-8
Diritti
open access
FVG url
https://arts.units.it/request-item?handle=11368/2962745
Soggetti
  • Cardiac Caval Index

  • Caval Index

  • Edge-tracking

  • Inferior vena cava

  • Respiratory Caval Ind...

  • Right atrial pressure...

Web of Science© citazioni
16
Data di acquisizione
Mar 26, 2024
Visualizzazioni
1
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback