Logo del repository
  1. Home
 
Opzioni

Optimization of pixel size and propagation distance in X-ray phase-contrast virtual histology

Donato, S
•
Arana Peña, L M
•
Bonazza, D
altro
Brombal, L
2022
  • journal article

Periodico
JOURNAL OF INSTRUMENTATION
Abstract
X-ray phase-contrast coupled to high-spatial resolution imaging systems provides a high sensitivity for distinguishing soft tissue structures in small samples, thus being suited for X-ray virtual histology. Propagation-based phase-contrast tomography can deliver a considerable gain in signal-to-noise ratio (SNR) at small pixel sizes when it is combined to a suitable phase retrieval filter. We optimized acquisition parameters, namely the propagation distance and the pixel size, with the aim of providing adequate spatial resolution and sensitivity for virtual histology of breast surgery specimens, scanned with a phase-contrast microtomography (mu CT) system employing a commercial sCMOS detector at the SYRMEP beamline of the Italian synchrotron facility Elettra (Trieste, Italy). A pathological breast tissue sample was embedded in paraffin and imaged using a polychromatic synchrotron beam at an average energy of 24 keV. The high numerical optical aperture of the imaging system enabled to adjust the pixel size to 1, 2.5 and 4 mu m. The scans were acquired at five sample-to-detector distances: 4.5, 150, 250, 500 and 1000 mm. SNR was measured in an homogeneous region portion of the mu CT image for each combination of pixel size and propagation distance. Experimental results were compared to a theoretical model taking into account the actual point spread function of the employed imaging system. The measured gain of SNR associated with the application of the phase-retrieval matched the predictions for large Fresnel numbers (N-F > 2). For each pixel size, an optimal range of propagation distances was found. Optimal mu CT reconstructions were then compared with their respective histopatological images, showing an excellent visibility of relevant structures. The optimization performed in this study will allow to select the most appropriate geometrical configurations for future acquisitions of virtual histology images of different specimens via phase-contrast microtomography.
DOI
10.1088/1748-0221/17/05/C05021
WOS
WOS:000800544800003
Archivio
https://hdl.handle.net/11368/3025233
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85130701777
https://iopscience.iop.org/article/10.1088/1748-0221/17/05/C05021
Diritti
open access
license:copyright editore
license:digital rights management non definito
license uri:iris.pri02
license uri:iris.pri00
FVG url
https://arts.units.it/request-item?handle=11368/3025233
Soggetti
  • Computerized Tomograp...

  • X-ray detector

  • Inspection with X-ray...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback