Logo del repository
  1. Home
 
Opzioni

Oxide ceramic femoral heads contribute to the oxidation of polyethylene liners in artificial hip joints

Pezzotti, Giuseppe
•
Zhu, Wenliang
•
Sugano, Nobuhiko
altro
Sonny Bal, B
2018
  • journal article

Periodico
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS
Abstract
Experimental evidence demonstrates that a loss of stoichiometry at the surface of oxide bioceramic femoral heads enhances the oxidation rate of polyethylene acetabular liners in artificial hip joints. Contradicting the common notion that ceramics are bioinert, three independent experiments confirmed substantial chemical interactions between the ceramic femoral heads and their polyethylene counterparts. The experiments reported herein included hydrothermal tests, frictional tests, and hip-simulator experiments. It was discovered that oxide and non-oxide femoral heads differently affected the oxidation processes at the surface of the polyethylene liners, all other testing parameters being equal. Analytical data from X-ray photoelectron (XPS), cath-odoluminescence (CL), Fourier-transform infrared (FTIR), and Raman spectroscopies unequivocally and consistently showed that the oxidation rate of polyethylene liners was greater when coupled with oxide as opposed to non-oxide ceramic heads. XPS analyses of O-Al-O bond fractions at the surface of a zirconia-toughened alumina (ZTA) short-term (20 months in vivo) femoral heads retrieval showed a similar to 50% reduction in favor of oxygen vacancy O-Al-V-O and hydroxylated Al-O-H bonds. Off-stoichiometry drifts were confirmed in vitro under both static and dynamic conditions. They triggered oxidation and tangibly affected an advanced highly cross-linked sequentially irradiated and annealed ultra-high molecular weight polyethylene (UHMWPE) liner (increase in oxidation index up to Delta OI similar to 1.2 after 5 x 10(5) cycles under dynamic swing conditions). Second-generation UHMWPE liners infused with vitamin E were also affected by the free flow of oxygen from the oxide femoral heads, although to a lesser extent. The fundamental findings of this study, which were also confirmed on re-trievals, call for revised standards in material design and testing. Adopting these new criteria will provide an improved understanding of the importance of off-stoichiometry at the head/liner interface and may lead to significant extensions in artificial joint lifetimes.
DOI
10.1016/j.jmbbm.2018.03.021
WOS
WOS:000432508800020
Archivio
https://hdl.handle.net/11390/1235858
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85044504496
https://ricerca.unityfvg.it/handle/11390/1235858
Diritti
metadata only access
Soggetti
  • Ceramic

  • Materials Testing

  • Mechanical Phenomena

  • Oxidation-Reduction

  • Polyethylene

  • Polyethylene

  • Prosthesis Design

  • Femur Head

  • Hip Prosthesis

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback