Logo del repository
  1. Home
 
Opzioni

Editor's Choice – Outcomes of Self Expanding PTFE Covered Stent Versus Bare Metal Stent for Chronic Iliac Artery Occlusion in Matched Cohorts Using Propensity Score Modelling

Piazza M.
•
Squizzato F.
•
Dall'Antonia A.
altro
Antonello M.
2017
  • journal article

Periodico
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY
Abstract
OBJECTIVES: The aim was to compare outcomes of self expanding PTFE covered stents (CSs) with bare metal stents (BMSs) in the treatment of iliac artery occlusions (IAOs). METHODS: Between January 2009 and December 2015, 128 iliac arteries were stented for IAO. A CS was implanted in 78 iliac arteries (61%) and a BMS in 50 (49%). After propensity score matching, 94 limbs were selected and underwent stenting (47 for each group). Thirty day outcomes and midterm patency were compared; follow-up results were analysed with Kaplan-Meier curves. RESULTS: Overall, iliac lesions were classified by limb as TASC B (19%), C (21%), and D (60%). Technical success was 98%. Comparing CS versus BMS, the early cumulative surgical complication rate (12% vs. 12%, p = 1.0) and 30 day mortality rate (2% vs. 2%, p = 1.0) were equivalent. At 36 months (average 23 ± 17), overall primary patency was similar between CS and BMS (87% vs. 66%, p = .06), and this finding was maintained after stratification by TASC B (p = .29) and C (p = .27), but for TASC D, CSs demonstrated a higher patency rate (CS, 88% vs. BMS, 54%; p = .03). In particular, patency was in favour of CSs for IAOs > 3.5 cm in length (p = .04), total lesion length > 6 cm (p = .04), and IAO with calcification > 75% of the arterial wall circumference (p = .01). CONCLUSIONS: Overall, the use of self expanding CS for IAOs has similar early and midterm outcomes compared with BMS. Even if further confirmatory studies are needed, CSs seem to have higher midterm patency rates than BMSs for TASC D lesions, IAOs with a total lesion length > 6 cm, occlusion length > 3.5 cm, and calcification involving > 75% of the arterial wall circumference. These specific anatomical parameters may be useful to the operator when deciding between CS and BMS during endovascular planning.
DOI
10.1016/j.ejvs.2017.03.019
WOS
WOS:000407536300008
Archivio
http://hdl.handle.net/11368/2953683
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85018395109
https://www.sciencedirect.com/science/article/pii/S1078588417302083?via=ihub
Diritti
open access
license:digital rights management non definito
license:digital rights management non definito
license:digital rights management non definito
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2953683
Soggetti
  • Hybrid procedure

  • Iliac artery occlusio...

  • Iliac stenting

  • Peripheral artery dis...

  • Stent

Scopus© citazioni
16
Data di acquisizione
Jun 7, 2022
Vedi dettagli
Web of Science© citazioni
25
Data di acquisizione
Mar 22, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback