Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescents

LAZZER, Stefano
•
BOIRIE Y
•
MEYER M
•
VERMOREL M.
2003
  • journal article

Periodico
BRITISH JOURNAL OF NUTRITION
Abstract
The objective of the present study was to determine the accuracy of two foot-to-foot (FF) bioelectrical impedance analysers (BIA) to assess body composition in overweight and obese adolescents, compared with dual-energy X-ray absorptiometry (DXA) and hand-to-foot (HF) BIA. Body composition was assessed in fifty-three overweight or obese adolescents (BMI 27.9 (SD 4.1) kg/m2; aged 13-16 years) by DXA (Hologic QDR-4500; Hologic Inc., Bedford, MA, USA) and BIA (HF (BIA 101, RJL System, Detroit, IL, USA) and FF (Body Fat Monitor Scale BF-625, Tanita Corporation of America Inc., Arlington Heights, IL, USA; Téfal Bodymaster Vision, Téfal, Rumilly, France)). Bland-Altman tests showed that, compared with DXA, FF-Tanita and FF-Téfal underestimated (P<0.05) fat mass (FM) less than HF-BIA (-1.7 (SD 3.1), -0.7 (SD 5.8) and -2.3 (SD 2.2) kg respectively, P<0.001). However, the limits of agreement between DXA and FF-Tanita or FF-Téfal were much greater than those obtained with HF-BIA (-7.7 and +4.3, - 12.0 and +10.6 v. -2.1 and +6.7 kg respectively). The differences between FM assessed using the FF-Tanita or the FF-Téfal analyser and DXA increased with the waist:hip ratio, and were higher in boys than in girls. The major limiting factor of FF-BIA was the inter-individual variability in FM estimates. In conclusion, FF-BIA and DXA are not interchangeable methods. FF-BIA could be acceptable to assess body composition in large groups of overweight or obese adolescents, but cannot be recommended for body composition assessment in obese subjects because of the large errors in individual estimates
WOS
WOS:000186370600015
Archivio
http://hdl.handle.net/11390/674297
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-0142198835
Diritti
closed access
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback