Logo del repository
  1. Home
 
Opzioni

Visual field endpoints based on subgroups of points may be useful in glaucoma clinical trials: A study with the humphrey field analyzer and compass perimeter

Barkana Y.
•
Leshno A.
•
Stern O.
altro
Skaat A.
2021
  • journal article

Periodico
JOURNAL OF GLAUCOMA
Abstract
Precis: Visual field (VF) endpoints based on average deviation of specific subsets of points rather than all points may offer a more homogeneous data set without necessarily worsening test-retest variability and so may be useful in clinical trials. Purpose: The purpose of this study was to characterize the outcome measures encompassing particular subsets of VF points and compare them as obtained with Humphrey [Humphrey visual field analyser (HVF)] and Compass perimeters. Methods: Thirty patients with imaging-based glaucomatous neuropathy performed a pair of 24-2 tests with each of 2 perimeters. Nonweighted mean deviation (MD) was calculated for the whole field and separate vertical hemifields, and again after censoring of points with low sensitivity (MDc) and subsequently including only “abnormal” points with a total deviation probability of < 5% (MDc5%) or <2% (MDc2%). Test-retest variability was assessed using Bland-Altman 95% limits of agreement (95%LoA). Results: For the whole field, using HVF, MD was −7.5 ± 6.9 dB, MDc −3.6 ± 2.8 dB, MDc5% −6.4 ± 1.7 dB, and MDc2% −7.3 ± 1.5 dB. With Compass the MD was −7.5 ± 6.6, MDc −2.9 ± 1.7 dB, MDc5% −6.3 ± 1.5, and MDC2% −7.9 ± 1.6. The respective 95%LoA were 5.5, 5.3, 4.6, and 5.6 with HVF, and 4.8, 3.7, 7.1, and 7.1 with Compass. The respective number of eligible points were 52, 42 ± 12, 20 ± 11, and 15 ± 9 with HVF, and 52, 41.2 ± 12.6, 10 ± 7, and 7 ± 5 with Compass. With both machines, SD and 95%LoA increased in hemifields compared with the total field, but this increase was mitigated after censoring. Conclusion: Restricting analysis to particular subsets of points of interest in the VF after censoring points with low sensitivity, as compared with using the familiar total field MD, can provide outcome measures with a broader range of MD, a markedly reduced SD and therefore more homogeneous data set, without necessarily worsening test-retest variability.
DOI
10.1097/IJG.0000000000001856
WOS
WOS:000685229000015
Archivio
http://hdl.handle.net/11390/1210998
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85113243158
https://ricerca.unityfvg.it/handle/11390/1210998
Diritti
metadata only access
Soggetti
  • Endpoint

  • Field

  • Glaucoma

  • Outcome measure

  • Sensitivity

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback