Abstract
Hematocrit (HCT) is a crucial parameter for both adult and pediatric patients, indicating potentially severe pathological conditions. Most common methods for HCT assessment are microhematocrit and automated analyzers; however, developing countries present specific needs often not addressed by these technologies. Paper-based devices can be suitable for those environments being inexpensive, rapid, easy to use, and portable. The aim of this study is to describe and validate against a reference method, a novel HCT estimation method based on penetration velocity in lateral flow test strips complying with the requirements in low- or middle-income country (LMIC) scenarios. To calibrate and test the proposed method, 145 blood samples of 105 healthy neonates with gestational age greater than 37 weeks were collected (29 calibration set, 116 test set) in the range of HCT values (31.6-72.5%). The time difference (Delta t) from the whole blood sample loading into the test strip instant till the nitrocellulose membrane saturation instant was measured by a reflectance meter. A nonlinear relation was observed between HCT and Delta t and was estimated by a third-degree polynomial equation (R-2 = 0.91) valid in 30% to 70% HCT interval. The proposed model was subsequently used to estimate HCT values on the test set showing a good agreement between the estimated HCT and the HCT measured by the reference method (r = 0.87, p < 0.001), with a low mean difference of 0.53 +/- 5.04% and a slight trend of overestimation for higher hematocrit values. The mean absolute error was 4.29%, while the maximum absolute error was 10.69%. Although the proposed method did not present a sufficient accuracy to be used for diagnostic purposes, it could be suitable as a fast, low-cost, easy-to-use screening tool especially in LMIC scenarios.
DOI
10.3390/s23052813
WOS
WOS:000947674200001
Archivio
https://hdl.handle.net/11368/3047579
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85149714557
https://www.mdpi.com/1424-8220/23/5/2813
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10006883/
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/3047579/1/sensors-23-02813.pdf
Soggetti
  • LMIC

  • hematocrit

  • lateral flow

  • neonatal care

  • point-of-care

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback