A global analysis of implants and replacements of pacemakers and cardioverter-defibrillators before, during, and after the COVID-19 pandemic in Italy

Zecchin, Massimo
•
Ciminello, Enrico
•
Mari, Veronica
altro
Torre, Marina
2024
  • journal article

Periodico
INTERNAL AND EMERGENCY MEDICINE
Abstract
At the beginning of the COVID-19 emergency, non-urgent surgical procedures had to be deferred, but also emergencies were reduced. To assess the global trend of pacemaker (PM) and implantable cardiac-defibrillator (ICD) procedures performed in Italy before, during, and after the first COVID-19 emergency, all the Italian hospital discharge records related to PM/ICD procedures performed between 2012 and 2021, sent to the National Institute of Health, were reviewed. Compared to 2019, in 2020, there was a reduction of first PM implants (52,216 to 43,962, -16%; p < 0.01), but not replacements (16,591 to 17,331, + 4%; p = 0.16). In particular, in April 2020, there was a drop of first implants (- 53,4% vs the average value of April 2018 and April 2019; p < 0.01), while the reduction of replacements was less evident (-32.6%; p = NS). In 2021, PM procedures increased to values similar to the pre-pandemic period. A reduction of ICD procedures was observed in 2020 (22,355, -7% toward 2019), mainly in April 2020 (- 46% vs April 2018/April 2019; p = 0.03). In 2021, the rate of ICD procedures increased (+ 14% toward 2020). A non-significant reduction of "urgent" procedures (complete atrioventricular block for PM and ventricular fibrillation for ICD), even in April 2020, was observed. In 2020, there was a reduction of first PM implants and ICDs, offset by increased activity in 2021. No decrease in PM replacements was observed, and the drop in "urgent" PM and ICD procedures was not statistically significant.
DOI
10.1007/s11739-023-03450-1
WOS
WOS:001100643000002
Archivio
https://hdl.handle.net/11368/3064980
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85175948248
https://link.springer.com/article/10.1007/s11739-023-03450-1
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/3064980/3/s11739-023-03450-1.pdf
Soggetti
  • COVID-19 pandemic

  • Hospital discharge re...

  • Implantable cardiover...

  • Lockdown

  • Pacemaker

  • Replacement

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback