Logo del repository
  1. Home
 
Opzioni

Filling ability of three variants of the single-cone technique with bioceramic sealer: a micro-computed tomography study

Angerame D.
•
De Biasi M.
•
Pecci R.
•
Bedini R.
2020
  • journal article

Periodico
JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE
Abstract
The present study evaluated the quality of single-cone root canal fillings with bioceramic (BC) sealer using three different techniques by means of micro-computed tomography (micro-CT). The canals of 30 extracted single-rooted permanent teeth were shaped with R40 Reciproc blue files and filled with the single-cone technique (SCT). BioRoot RCS BC sealer was placed inside the canals with one of the following master cones: R40 cone to working length (RWL, n = 10); R40 cone trimmed 1 mm short of working length (RWL-1, n = 10); non-standardized gutta-percha cone to working length (NSWL, n = 10). A quantitative and qualitative micro-CT analysis assessed the filling quality and internal/external voids formation. Collected data underwent statistical analysis by multivariate one-way analysis of variance (α = 0.05). In all groups, the voids were minimal and prevalently external. The NSWL and RWL-1 groups had increased sealer ratios in the whole canal and the apical canal portion, respectively. The lowest amounts of voids were found in the RWL group; the void volumes were slightly greater in the RWL-1 mm and NSWL groups, especially at the apical level. Two alternative SCTs showed satisfactory filling ability, uniform distribution of the BC sealer, and a minimally increased voids formation compared to the standard SCT with dedicated cone. The two tested alternative SCTs could take advantage of the beneficial characteristics of the BC sealer, which evenly filled the endodontic space, ideally sealing both the major and the accessory communications with the periodontium. [Figure not available: see fulltext.]
DOI
10.1007/s10856-020-06443-0
WOS
WOS:000587291700002
Archivio
http://hdl.handle.net/11368/2979865
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85093075758
https://link.springer.com/article/10.1007/s10856-020-06443-0
Diritti
closed access
license:copyright editore
FVG url
https://arts.units.it/request-item?handle=11368/2979865
Soggetti
  • single-cone technique...

  • bioceramic sealer

  • sealer insertion tech...

  • endodontic treament

  • micro-computed tomogr...

Web of Science© citazioni
9
Data di acquisizione
Mar 15, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback