Logo del repository
  1. Home
 
Opzioni

Reproducibility of Macular Thickness Measurements Using Cirrus SD-OCT in Neovascular Age-Related Macular Degeneration

Parravano, M.
•
Oddone, F.
•
Boccassini, B.
altro
Varano, M.
2010
  • journal article

Periodico
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Abstract
PURPOSE. To assess the test-retest variability of central and sectorial macular thickness measurements obtained by Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA) in neovascular age-related macular degeneration (nAMD). METHODS. Macular thickness measurements of nine standard ETDRS subfields were obtained and analyzed. The repeatability of macular thickness measurements by Cirrus HD-OCT was assessed by examining the intrasession within subject standard deviation (Sw), coefficient of repeatability (CR), and coefficient of variation (CV), before and after eyes with retinal segmentation errors were excluded. RESULTS. Forty-nine nAMD eyes of 49 consecutive patients were included in the study. The CR for the central macular subfield was 42.4 mu m (10.5%) and ranged from 12.1 mu m (3.7%) for the outer nasal to 41.8 mu m (11.4%) for the inner nasal subfields. In a secondary analysis, eyes affected by erroneous detection of inner and outer retinal boundaries (6/49, 12.24%) were excluded. The revised coefficient of repeatability for the central macular subfield was 26.1 mu m (8.1%) and ranged from 10.3 mu m (3.8%) for the outer superior to 30.2 mu m (8.3%) for the inner nasal subfields. CONCLUSIONS. Overall, the test-retest variability of Cirrus HD-OCT is good for the central and sectorial macular subfields, with a low incidence of scan artifacts. (Invest Ophthalmol Vis Sci. 2010;51:4788 - 4791) DOI:10.1167/iovs.09-4976
DOI
10.1167/iovs.09-4976
WOS
WOS:000281502700058
Archivio
http://hdl.handle.net/11390/862934
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-77957375463
Diritti
metadata only access
Scopus© citazioni
28
Data di acquisizione
Jun 2, 2022
Vedi dettagli
Web of Science© citazioni
32
Data di acquisizione
Mar 13, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback