Logo del repository
  1. Home
 
Opzioni

The MAPS based PXL vertex detector for the STAR experiment

Contin, G.
•
Anderssen, E.
•
Greiner, L.
altro
Woodmansee, S.
2015
  • conference object

Periodico
JOURNAL OF INSTRUMENTATION
Abstract
The Heavy Flavor Tracker (HFT) was installed in the STAR experiment for the 2014 heavy ion run of RHIC. Designed to improve the vertex resolution and extend the measurement capabilities in the heavy flavor domain, the HFT is composed of three different silicon detectors based on CMOS monolithic active pixels (MAPS), pads and strips respectively, arranged in four concentric cylinders close to the STAR interaction point. The two innermost HFT layers are placed at a radius of 2.7 and 8 cm from the beam line, respectively, and accommodate 400 ultra-thin (50μm) high resolution MAPS sensors arranged in 10-sensor ladders to cover a total silicon area of 0.16m2 . Each sensor includes a pixel array of 928 rows and 960 columns with a 20.7μm pixel pitch, providing a sensitive area of ∼ 3.8 cm2 . The architecture is based on a column parallel readout with amplification and correlated double sampling inside each pixel. Each column is terminated with a high precision discriminator, is read out in a rolling shutter mode and the output is processed through an integrated zero suppression logic. The results are stored in two SRAM with ping-pong arrangement for a continuous readout. The sensor features 185.6μs readout time and 170mW/cm2 power dissipation. The detector is aircooled, allowing a global material budget as low as 0.39% on the inner layer. A novel mechanical approach to detector insertion enables effective installation and integration of the pixel layers within an 8 hour shift during the on-going STAR run. In addition to a detailed description of the detector characteristics, the experience of the first months of data taking will be presented in this paper, with a particular focus on sensor threshold calibration, latch-up protection procedures and general system operations aimed at stabilizing the running conditions. Issues faced during the 2014 run will be discussed together with the implemented solutions. A preliminary analysis of the detector performance meeting the design requirements will be reported.
DOI
10.1088/1748-0221/10/03/C03026
WOS
WOS:000357944500026
Archivio
http://hdl.handle.net/11368/2942048
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84950313675
http://iopscience.iop.org/article/10.1088/1748-0221/10/03/C03026/pdf
Diritti
closed access
license:copyright editore
FVG url
https://arts.units.it/request-item?handle=11368/2942048
Soggetti
  • Detector design and c...

  • Particle tracking det...

  • Instrumentation

  • Mathematical Physics

Web of Science© citazioni
11
Data di acquisizione
Mar 25, 2024
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback