Melt pelletization in high shear mixer using a hydrophobic melt binder: influence of some apparatus and process variables.

VOINOVICH, DARIO
•
MONEGHINI, MARIAROSA
•
PERISSUTTI, Beatrice
•
FRANCESCHINIS E.
2001
  • journal article

Periodico
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS
Abstract
The effects of process conditions and the apparatus variables on the granulometric characteristics of a formulation containing a hydrophobic binder (stearic acid), lactose and paracetamol prepared by melt pelletization process were investigated in a 10-litre high shear mixer. The factors under investigation were: impeller speed, massing time, type of impeller blades and presence of the deflector and their reciprocal interactions. Two granule characteristics were analysed: the percentage of aggregates larger than 3000 μm (Y1) and the yield of the 2000-μm pellet size fraction (Y2). In order to estimate simultaneously the above-mentioned factors, a particular experimental design was adopted, that allowed the reduction of the number of trials from 378 to 35 and took into consideration other uncontrolled factors with the aid of a block variable. Using the postulated model, we found the optimal operating conditions to minimize Y1 and increase Y2 by selecting the type of impeller, and by using an impeller speed lower than 300 rpm, a massing time of 8-9 min and by not using the deflector. Finally, the validity of the adopted strategy has been proved with an additional check point.
DOI
10.1016/S0939-6411(01)00196-5
WOS
WOS:000172338300006
SCOPUS
2-s2.0-0034757135
Archivio
http://hdl.handle.net/11368/1727947
Diritti
metadata only access
Soggetti
  • 10 liter High shear m...

  • D-optimal design

  • Melt pelletization,

  • Paracetamol,

  • Stearic acid

Web of Science© citazioni
25
Data di acquisizione
Mar 28, 2024
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback