Logo del repository
  1. Home
 
Opzioni

Development and validation of LC-MS/MS method for imatinib and norimatinib monitoring by finger-prick DBS in gastrointestinal stromal tumor patients

Iacuzzi, Valentina
•
Posocco, Bianca
•
ZANCHETTA, MARTINA
altro
Toffoli, Giuseppe
2019
  • journal article

Periodico
PLOS ONE
Abstract
The introduction of imatinib, an oral tyrosine kinase inhibitor, as first-line standard therapy in patients with unresectable, metastatic, or recurrent gastro-intestinal stromal tumor (GIST), strongly improved their treatment outcomes. However, therapeutic drug monitoring (TDM) is recommended for this drug due to the large inter-individual variability in plasma concentration when standard dose is administered. A Cmin higher than 760 ng/mL was associated with a longer progression free survival. Thus, a LC-MS/MS method has been developed and fully validated to quantify imatinib and its active metabolite, norimatinib, in finger-prick dried blood spot (DBS). The influence of hematocrit, sample homogeneity, and spot size and the correlation between finger-prick and venous DBS measurements were also assessed. The method showed a good linearity (R2 > 0,996) between 50-7500 ng/mL for imatinib and 10-1500 ng/mL for norimatinib. Analytes were extracted from DBS samples by simply adding to 3 mm-discs 150 μL of acidified methanol containing IMA-D8. The collected extract was then injected on a LC Nexera system in-house configured for the on-line cleanup, coupled with an API-4000 QT. The chromatographic separation was conducted on a Synergi Fusion-RP column (4 μm, 2x50 mm) while the trapping column was a POROS R1/20 (20 μm, 2x30 mm). The total run time was 8.5 min. DBSs stored at room temperature in plastic envelopes containing a silica-gel drying bag were stable up to 16 months. The proposed method was applied to 67 clinical samples, showing a good correlation between patients' finger-prick DBS and plasma concentrations, measured by the reference LC-MS/MS method, internally validated. Imatinib and norimatinib concentrations found in finger-prick DBS were adjusted by hematocrit or by an experimental correction factor to estimate the corresponding plasma measurements. At the best of our knowledge, the proposed LC-MS/MS method is the first analytical assay to measure imatinib and norimatinib in DBS samples.
DOI
10.1371/journal.pone.0225225
WOS
WOS:000533877300024
Archivio
http://hdl.handle.net/11368/2953279
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85075259738
https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0225225
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/2953279/2/journal.pone.0225225.pdf
Soggetti
  • LC-MS/MS

  • DBS

  • imatinib

  • norimatinib

Scopus© citazioni
9
Data di acquisizione
Jun 15, 2022
Vedi dettagli
Web of Science© citazioni
19
Data di acquisizione
Mar 21, 2024
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback