Logo del repository
  1. Home
 
Opzioni

Impact of clinical data on chest radiography sensitivity in detecting pulmonary abnormalities in immunocompromised patients with suspected pneumonia

Cereser, L.
•
ZUIANI, Chiara
•
Graziani, G.
altro
BAZZOCCHI, Massimo
2010
  • journal article

Periodico
LA RADIOLOGIA MEDICA
Abstract
Find full text(opens in a new window)|Order document(opens in a new window)|View at Publisher| Export | Download | Add to List | More... Radiologia Medica Volume 115, Issue 2, March 2010, Pages 205-214 Impact of clinical data on chest radiography sensitivity in detecting pulmonary abnormalities in immunocompromised patients with suspected pneumonia (Article) [Impatto della conoscenza delle informazioni cliniche sulla sensibilità del radiogramma del torace nel riconoscimento di infiltrati polmonari in pazienti immunocompromessi con sospetta polmonite] Cereser, L.a , Zuiani, C.a, Graziani, G.a, Girometti, R.a, Como, G.a, Zaja, F.b, Bazzocchi, M.a a Istituto di Radiologia, Università Degli Studi di Udine, Via Colugna 50, Udine 33100, Italy b Clinica Ematologica, Università Degli Studi di Udine, Piazza Santa Maria della Misericordia, Udine 33100, Italy View references (25) Abstract Purpose: Chest radiography (CXR) of immunocompromised patients has low sensitivity in the early evaluation of pulmonary abnormalities suspected to be infectious. The purpose of the study was to evaluate whether the knowledge of clinical data improves the diagnostic sensitivity of CXR in the particular setting of immunocompromised patients after hematopoietic stem cell transplantation (HSCT). Materials and methods: Sixty-four CXRs of immunocompromised patients with clinically suspected pneumonia were retrospectively and independently evaluated by two radiologists to assess the presence of radiological signs of pneumonia, before (first reading) and after (second reading) the knowledge of clinical data. A chest computed tomography (CT) performed within 3 days was assumed as the standard of reference. For each reading, sensitivity of both radiologists was calculated. Results: Readers showed a sensitivity of 39% and 58.5% for the first reading, and 43.9% and 41.5% for the second reading, respectively. For both readers, these values were not significantly different from those obtained at first reading (McNemar's test, p>0.05). Interobserver agreement at second reading was fair (Cohen test, k=0.33). Conclusions: The sensitivity of CXR is too low to consider it a stand-alone technique for the evaluation of immunocompromised patients after HSCT with suspected pneumonia, even if the radiologist knows detailed clinical data. For these patients, an early chest CT evaluation is therefore recommended.
DOI
10.1007/s11547-009-0433-3
WOS
WOS:000276098100003
Archivio
http://hdl.handle.net/11368/2953528
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-77951296738
http://link.springer.com/article/10.1007/s11547-009-0433-3
Diritti
metadata only access
Soggetti
  • Chest radiography

  • Hematopoietic stem ce...

  • Immunocompromised pat...

  • Pneumonia

  • Adult

  • Aged

  • Diagnosi

  • Differential

  • Female

  • Human

  • Male

  • Middle Aged

  • Pneumonia

  • Predictive Value of T...

  • Radiographic Image In...

  • Computer-Assisted

  • Radiography

  • Thoracic

  • Retrospective Studie

  • Sensitivity and Speci...

  • Tomography

  • X-Ray Computed

  • Hematopoietic Stem Ce...

  • Immunocompromised Hos...

  • Radiology

  • Nuclear Medicine and ...

  • Medicine (all)

Web of Science© citazioni
13
Data di acquisizione
Mar 18, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback