Logo del repository
  1. Home
 
Opzioni

Reproducibility and Reliability of Spectralis II OCT Angiography Vascular Measurements

Pastore, Marco R.
•
Grotto, Alberto
•
Vezzoni, Francesca
altro
Tognetto, Daniele
2022
  • journal article

Periodico
DIAGNOSTICS
Abstract
Purpose: to investigate the reproducibility and reliability of OCT-A vascular measurements using Heidelberg Spectralis II OCT-A. Methods: a prospective study involving a single eye of patients aged 18 or older with no ocular disease. In order to investigate the reliability of the first and second OCT-A scans, the coefficient of variation of the foveal avascular zone (FAZ) and the vessel density (VD) in the superficial (SCP), intermediate (ICP) and deep capillary plexus (DCP) were calculated. Results: A total of 75 eyes were included in the study. The mean FAZ in the first and second scan was 0.36 × 0.13 mm2 and 0.37 × 0.12 mm2, respectively, in the SCP, 0.23 × 0.10 mm2 and 0.23 × 0.09 mm2 in the ICP, and 0.42 × 0.11 mm2 and 0.43 × 0.12 mm2 in the DCP. The overall VD was 36.05 × 9.01 and 35.33 × 9.92 at the first and second scan, respectively, in the SCP, 21.87 × 5.00 and 21.32 × 5.56 in the ICP, and 23.84 × 6.53 and 23.20 × 6.83 in the DCP. No statistically significant differences in FAZ measurements and VD in all sectors of each capillary plexus were observed between the first and second scan (p > 0.05). Conclusion: our study demonstrated the good reproducibility and reliability of OCT-A vascular measurements in the analysis of the FAZ and the quantification of VD in each capillary plexus of the retina.
DOI
10.3390/diagnostics12081908
WOS
WOS:000845937600001
Archivio
http://hdl.handle.net/11368/3027706
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85137412078
https://www.mdpi.com/2075-4418/12/8/1908
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9406840/
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
Soggetti
  • retinal microvasculat...

  • optical coherence tom...

  • reliability

  • reproducibility

  • foveal avascular zone...

  • vessel density

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback