The catheter-to-vein ratio at the tip level, not the catheter type, as a risk factor for a catheter failure. A retrospective comparative study of polyurethane midline and long peripheral catheters

FABIANI, Adam
•
SANTORO, Marilena
•
SANSON, Gianfranco
2023
  • journal article

Periodico
HEART & LUNG
Abstract
Background: In patients requiring a peripheral venous access for more than seven days, long peripheral catheters (LPCs) or midline catheters (MCs) are recommended. Since MCs and LPCs share many characteristics, studies comparing devices made of the same biomaterial are needed. Moreover, a catheter-to-vein ratio >45% at the insertion point has been recognized as a risk factor for catheter related complications, but no study investigated the effect of the catheter-to-vein ratio at the catheter tip level in peripheral venous devices. Objectives: To compare the catheter failure risk between polyurethane MCs and LPCs, considering the effect of the catheter-to-vein ratio at the tip location. Methods: Retrospective cohort study. Adult patients having an expected need for a vascular access of more than 7 days and receiving either a polyurethane LPC or MC were included. The catheter uncomplicated indwelling time within 30 days was considered in survival analysis. Results: In a sample of 240 patients, the relative incidences of catheter failure were 5.13 and 3.40 cases for 1,000 catheter days for LPCs and MCs, respectively. In univariate Cox regression, MCs were associated to a statistically significant lower risk of catheter failure (HR 0.330; p = 0.048). After adjusting for other relevant conditions, a catheter-to-vein ratio >45% at the catheter tip location not the catheter itself was an independent predictor of a catheter failure (HR 6.762; p = 0.023). Conclusions: The risk of catheter failure was strongly associated with a catheter-to-vein ratio > 45% at the catheter tip level, irrespective for having used a polyurethane LPC or MC.
DOI
10.1016/j.hrtlng.2023.02.027
WOS
WOS:000954937500001
Archivio
https://hdl.handle.net/11368/3041266
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85149721272
https://www.sciencedirect.com/science/article/pii/S0147956323000572
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/4.0/
FVG url
https://arts.units.it/bitstream/11368/3041266/3/1-s2.0-S0147956323000572-main.pdf
Soggetti
  • Midline catheter

  • Long peripheral cathe...

  • Catheter-to-vein rati...

  • Catheter failure

  • Catheter related comp...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback