Is high pressure postdilation safe in bioresorbable vascular scaffolds? Optical coherence tomography observations after noncompliant balloons inflated at more than 24 atmospheres

FABRIS, ENRICO
•
Caiazzo, Gianluca
•
Kilic, Ismail Dogu
altro
Di Mario, Carlo
2016
  • journal article

Periodico
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS
Abstract
OBJECTIVES: Optical coherence tomography (OCT) was used to investigate integrity and expansion of bioresorbable drug-eluting scaffolds (BVS) after high-pressure postdilation (HPPD). BACKGROUND: Because of concerns about the risk of BVS damage, postdilation was not recommended and applied in the existing randomized studies and most registries. Recent real world data suggest incomplete BVS expansion cause higher rates of thrombosis. In vivo confirmation of the safety of high pressure postdilation is of paramount importance. METHODS: Data from final OCT examination of consecutive implanted BVS, postdilated with noncompliant (NC) balloons at pressure ≥24 atm were analyzed. The following stent performance indices were assessed with OCT: mean and minimal lumen and scaffold area, residual area stenosis (RAS), incomplete strut apposition (ISA), tissue prolapse, eccentricity index (EI), symmetry index (SI), strut fractures, and edge dissections. RESULT: Twenty-two BVS postdilated at high pressure were analyzed. The average maximal postdilation balloon inflation (maxPD) was 28 ± 3 atm. High pressure OPN NC Balloon (SIS Medical AG, Winterthur Switzerland) was used in 41% of postdilations with a maximal PD of 30 ± 4.7 atm. Final mean and minimal lumen area were 6.8 ± 1.4 and 5.5 ± 1.4 mm(2) , respectively. OCT showed low percentage of RAS (16 ± 9.6%), and low percentage of ISA (1.8 ± 2.4%). Mean EI was 0.86 ± 0.02 and SI 0.35 ± 0.14. OCT analysis showed one edge dissection and no scaffold fractures. CONCLUSIONS: BVS deployment optimization using HPPD does not cause BVS disruption and is associated with a good BVS expansion, low rate of strut malapposition and edge dissections.
DOI
10.1002/ccd.26222
WOS
WOS:000374483300011
Archivio
http://hdl.handle.net/11368/2878335
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84941585573
http://onlinelibrary.wiley.com/wol1/doi/10.1002/ccd.26222/full
Diritti
closed access
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2878335
Soggetti
  • bioresorbable vascula...

  • coronary angioplasty

  • noncompliant balloon

  • optical coherence tom...

  • struts apposition

  • Cardiology and Cardio...

  • Radiology, Nuclear Me...

Scopus© citazioni
25
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
25
Data di acquisizione
Mar 20, 2024
Visualizzazioni
3
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback