Acute and chronic high-frequency properties of cardiac pacing and defibrillation leads

TOMASIC, DANKO
•
Ferek Petric, Bozidar
•
Brusich, Sandro
•
ACCARDO, AGOSTINO
2012
  • journal article

Periodico
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING
Abstract
The purpose of our study was to investigate variety of cardiac lead conductor designs as high-frequency (HF) transmission lines. Special attention was given on evaluation of chronic HF applications in cardiac electrotherapy. We measured the characteristic impedance and the attenuation coefficient of six pacing leads between 1 and 21 MHz. They were subsequently immersed into the saline solution simulating the body fluid and the measurements were repeated 10 years later. Identical measurements were performed on 15 new pacing and defibrillation leads. The results revealed that lead geometry is the main factor affecting the HF parameters. Attenuation coefficients of old and contemporary leads do not differ significantly. Penetration of saline within the leads during a decade did not influence much their HF characteristics. Thus, a chronic cardiac contraction sensor based on lead’s HF impedance variation is feasible. The signal losses of ultrasonic transducers mounted on the lead might be stable for years at acceptable levels without significant variation. Due to mutually similar values of HF parameters in different leads, design of tensiometric or ultrasonic applications could be universal for majority of commercially available leads. Automatic system calibration could be developed for each and every lead after determination of its HF parameters.
DOI
10.1007/s11517-012-0935-3
WOS
WOS:000306953700004
Archivio
http://hdl.handle.net/11368/2561902
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84864342383
Diritti
metadata only access
Soggetti
  • defibrillation

  • cardiac pacing

Scopus© citazioni
2
Data di acquisizione
Jun 15, 2022
Vedi dettagli
Web of Science© citazioni
2
Data di acquisizione
Mar 28, 2024
Visualizzazioni
4
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback