Changes in Right Ventricular-to-Pulmonary Artery Coupling After Transcatheter Edge-to-Edge Repair in Secondary Mitral Regurgitation

Adamo, Marianna
•
Inciardi, Riccardo Maria
•
Tomasoni, Daniela
altro
Metra, Marco
2022
  • journal article

Periodico
JACC: CARDIOVASCULAR IMAGING
Abstract
Background: Preprocedural right ventricular-to-pulmonary artery (RV-PA) coupling is a major predictor of outcome in patients with secondary mitral regurgitation (SMR) undergoing transcatheter edge-to-edge mitral valve repair (M-TEER). However, clinical significance of changes in RV-PA coupling after M-TEER is unknown. Objectives: The aim of this study was to evaluate changes in RV-PA coupling after M-TEER, their prognostic value, and predictors of improvement. Methods: This was a retrospective observational study, including patients undergoing successful M-TEER (residual mitral regurgitation ≤2+ at discharge) for SMR at 13 European centers and with complete echocardiographic data at baseline and short-term follow-up (30-180 days). RV-PA coupling was assessed with the use of echocardiography as the ratio of tricuspid annular plane systolic excursion to pulmonary artery systolic pressure (TAPSE/PASP). All-cause death was assessed at the longest available follow-up starting from the time of the echocardiographic reassessment. Results: Among 501 patients included, 331 (66%) improved their TAPSE/PASP after M-TEER (responders) at short-term follow-up (median: 89 days; IQR: 43-159 days), whereas 170 (34%) did not (nonresponders). Lack of previous cardiac surgery, low postprocedural mitral mean gradient, low baseline TAPSE, high baseline PASP, and baseline tricuspid regurgitation were independently associated with TAPSE/PASP improvement after M-TEER. Compared with nonresponders, responders had lower New York Heart Association functional class and less heart failure hospitalizations at short-term follow-up. Improvement in TAPSE/PASP was independently associated with reduced risk of mortality at long-term follow-up (584 days; IQR: 191-1,243 days) (HR: 0.65 [95% CI: 0.42-0.92]; P = 0.017). Conclusions: In patients with SMR, improvement in TAPSE/PASP after successful M-TEER is predicted by baseline clinical and echocardiographic variables and postprocedural mitral gradient, and is associated with a better outcome.
DOI
10.1016/j.jcmg.2022.08.012
WOS
WOS:001044228700003
Archivio
https://hdl.handle.net/11368/3036000
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85142389057
https://www.sciencedirect.com/science/article/abs/pii/S1936878X22004971?via=ihub
Diritti
open access
license:copyright editore
license:digital rights management non definito
license uri:iris.pri02
license uri:iris.pri00
FVG url
https://arts.units.it/request-item?handle=11368/3036000
Soggetti
  • right ventricular to ...

  • secondary mitral regu...

  • transcatheter edge-to...

google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback