GEANT4 for breast dosimetry: parameters optimization study

FEDON, CHRISTIAN
•
LONGO, FRANCESCO
•
Mettivier, G.
•
LONGO, RENATA
2015
  • journal article

Periodico
PHYSICS IN MEDICINE AND BIOLOGY
Abstract
Mean glandular dose (MGD) is the main dosimetric quantity in mammography. MGD evaluation is obtained by multiplying the entrance skin air kerma (ESAK) by normalized glandular dose (DgN) coefficients. While ESAK is an empirical quantity, DgN coefficients can only be estimated with Monte Carlo (MC) methods. Thus, a MC parameters benchmark is needed for effectively evaluating DgN coefficients. GEANT4 is a MC toolkit suitable for medical purposes that offers to the users several computational choices. In this work we investigate the GEANT4 performances testing the main PhysicsLists for medical applications. Four electromagnetic PhysicsLists were implemented: the linear attenuation coefficients were calculated for breast glandularity 0%, 50%, 100% in the energetic range 8-50 keV and DgN coefficients were evaluated. The results were compared with published data. Fit equations for the estimation of the G-factor parameter, introduced by the literature for converting the dose delivered in the heterogeneous medium to that in the glandular tissue, are proposed and the application of this parameter interaction-by-interaction or retrospectively is discussed. G4EmLivermorePhysicsList shows the best agreement for the linear attenuation coefficients both with theoretical values and published data. Moreover, excellent correlation factor ([Formula: see text]) is found for the DgN coefficients with the literature.The final goal of this study is to identify, for the first time, a benchmark of parameters that could be useful for future breast dosimetry studies with GEANT4.
DOI
10.1088/0031-9155/60/16/N311
WOS
WOS:000361052600002
Archivio
http://hdl.handle.net/11368/2845258
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-84939151927
Diritti
open access
license:digital rights management non definito
license:creative commons
license uri:http://creativecommons.org/licenses/by-nd/3.0/it/
FVG url
https://arts.units.it/request-item?handle=11368/2845258
Soggetti
  • breast dosimetry

  • GEANT4

  • Monte Carlo code

Web of Science© citazioni
47
Data di acquisizione
Mar 28, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback