Logo del repository
  1. Home
 
Opzioni

A proposal for a quality control protocol in breast CT with synchrotron radiation

Contillo, Adriano
•
Veronese, Anna
•
Brombal, Luca
altro
Arfelli, Fulvia
2018
  • journal article

Periodico
RADIOLOGY AND ONCOLOGY
Abstract
The SYRMA-3D collaboration is setting up the first clinical trial of phase-contrast breast CT with synchrotron radiation at the Elettra synchrotron facility in Trieste, Italy. In this communication, a quality control protocol for breast CT is proposed, and a first test of image quality measurements is performed by means of a custom-made radiographic phantom. Materials and methods A set of projections is acquired and used to perform a CT reconstruction of two selected portions of the phantom. Such portions contain a uniform layer of water and a set of radiographic inserts, respectively. Together, they allow to perform several image quality measurements, namely CT number linearity, reconstruction accuracy, uniformity, noise, and low contrast resolution. All measurements are repeated at different beam energies in the range of interest, and at two different dose values. Results Measurements show a good linearity in the soft tissue range, paired to a high accuracy of the CT number reconstruction. Uniformity and noise measurements show that reconstruction inhomogeneities are bound to a few percent of the average pixel values. However, low contrast detectability is limited to the higher portion of the explored energy range. Conclusions The results of the measurements are satisfactory in terms of their quality, feasibility and reproducibility. With minimal modifications, the phantom is promising to allow a set of image quality measurements to be used in the upcoming clinical trial.
DOI
10.2478/raon-2018-0015
WOS
WOS:000443852900013
Archivio
http://hdl.handle.net/11368/2926777
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85045855468
https://content.sciendo.com/view/journals/raon/52/3/article-p329.xml
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by-nc-nd/4.0/
FVG url
https://arts.units.it/bitstream/11368/2926777/4/[15813207 - Radiology and Oncology] A proposal for a quality control protocol in breast CT with synchrotron radiation.pdf
Soggetti
  • breast CT

  • quality control

  • radiographic phantom

  • synchrotron radiation...

  • Oncology

  • Radiology, Nuclear Me...

Scopus© citazioni
8
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
9
Data di acquisizione
Mar 25, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback