Perioperative considerations in patients with cirrhotic cardiomyopathy.

Biancofiore G
•
Mandell MS
•
DELLA ROCCA, Giorgio
2010
  • journal article

Periodico
CURRENT OPINION IN ANAESTHESIOLOGY
Abstract
PURPOSE OF REVIEW: This review aims to identify specific criteria for cirrhotic cardiomyopathy, examine the correlation with perioperative adverse outcomes and explore options for hemodynamic monitoring. RECENT FINDINGS: Cirrhotic cardiomyopathy is characterized by an increase in cardiac output, blunted systolic contractile response to stress, diastolic dysfunction and electrophysiological abnormalities. Adverse events due to cirrhotic cardiomyopathy are not as well characterized, but evidence suggests that some cardiovascular complications during surgery and in the postoperative period are caused by an impaired response to physiological stress. New developments in hemodynamic monitoring using not only thermodilution technology provide more reliable information about cardiac performance than pressure-derived measures. Transesophogeal echocardiography also offers the physician new information including the ability to visualize heart structures, shape, and function. SUMMARY: To detect cirrhotic cardiomyopathy, physicians must conduct a systematic examination of the patient. Overt manifestations of cirrhotic cardiomyopathy often only become evident after a patient is exposed to physiological or drug-induced stress. Appropriate hemodynamic monitoring is a cornerstone in the perioperative management of cirrhotic patients.
DOI
10.1097/ACO.0b013e328337260a
WOS
WOS:000275817300002
Archivio
http://hdl.handle.net/11390/697710
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-77952233306
Diritti
closed access
Scopus© citazioni
14
Data di acquisizione
Jun 2, 2022
Vedi dettagli
Web of Science© citazioni
11
Data di acquisizione
Mar 27, 2024
Visualizzazioni
2
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback