Logo del repository
  1. Home
 
Opzioni

Performance of the ForenSeqTM DNA Signature Prep kit on highly degraded samples

FATTORINI, PAOLO
•
Previderé, Carlo
•
Carboni, Ilaria
altro
Ricci, Ugo
2017
  • journal article

Periodico
ELECTROPHORESIS
Abstract
Next generation sequencing (NGS) is the emerging technology in forensic genomics laboratories. It offers higher resolution to address most problems of human identification, greater efficiency and potential ability to interrogate very challenging forensic casework samples. In this study, a trial set of DNA samples was artificially degraded by progressive aqueous hydrolysis, and analyzed together with the corresponding unmodified DNA sample and control sample 2800 M, to test the performance and reliability of the ForenSeqTM DNA Signature Prep kit using the MiSeq Sequencer (Illumina). The results of replicate tests performed on the unmodified sample (1.0 ng) and on scalar dilutions (1.0, 0.5 and 0.1 ng) of the reference sample 2800 M showed the robustness and the reliability of the NGS approach even from sub-optimal amounts of high quality DNA. The degraded samples showed a very limited number of reads/sample, from 2.9–10.2 folds lower than the ones reported for the less concentrated 2800 M DNA dilution (0.1 ng). In addition, it was impossible to assign up to 78.2% of the genotypes in the degraded samples as the software identified the corresponding loci as “low coverage” ( 50x). Amplification artifacts such as allelic imbalances, allele drop outs and a single allele drop in were also scored in the degraded samples. However, the ForenSeqTM DNA Sequencing kit, on the Illumina MiSeq, was able to generate data which led to the correct typing of 5.1–44.8% and 10.9–58.7% of 58 of the STRs and 92 SNPs, respectively. In all trial samples, the SNP markers showed higher chances to be typed correctly compared to the STRs. This NGS approach showed very promising results in terms of ability to recover genetic information from heavily degraded DNA samples for which the conventional PCR/CE approach gave no results. The frequency of genetic mistyping was very low, reaching the value of 1.4% for only one of the degraded samples. However, these results suggest that further validation studies and a definition of interpretation criteria for NGS data are needed before implementation of this technique in forensic genetics.
DOI
10.1002/elps.201600290
WOS
WOS:000399694700008
Archivio
http://hdl.handle.net/11368/2901172
info:eu-repo/semantics/altIdentifier/scopus/2-s2.0-85012101513
http://onlinelibrary.wiley.com/doi/10.1002/elps.201600290/full
Diritti
open access
license:digital rights management non definito
license:digital rights management non definito
FVG url
https://arts.units.it/request-item?handle=11368/2901172
Soggetti
  • DNA degradation, For...

Web of Science© citazioni
51
Data di acquisizione
Mar 22, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback