Logo del repository
  1. Home
 
Opzioni

Bio-medical X-ray imaging with Synchrotron Radiation: study and implementation of algorithms related to phase sensitive techniques

Mohammadi, Sara
2013-04-11
  • Controlled Vocabulary...

Abstract
Phase-contrast X-ray imaging is an invaluable tool in medical diagnostics and biological sciences. It provides images where both absorption and refraction contribute. For quantitative analysis of these images, the phase needs to be retrieved numerically. There are many phase-retrieval methods available. My thesis aims to optimize the application of phase retrieval methods for different phase-contrast imaging situations. A quantitative comparison between phase contrast and phase retrieved images is also performed on some selected examples. We analyzed the two most-applied phase retrieval algorithms and outlined derivations, approximations and assumptions of each one. We implemented these algorithms on experimental data collected at the SYRMEP beam-line of ELETTRA, Italy. We used the algorithms based on Born approximation and transport-of-intensity equation (TIE) for different kinds of test objects and biological samples (high absorbing, homogeneous, low absorbing, etc.) at various experimental conditions (sample-to-detector distances, energies, detector resolutions). Their capability and restriction are evaluated in the visualization of the sample morphology up to its tiniest details. It was shown that Born method is highly depended on phase and intensity distributions in the object plane, being quite accurate in the case of small phase variations and low absorption materials. On the other side, the TIE approximation did not impose any direct limitations on phase and intensity distributions in the object-plane or image-plane but its application is restricted to near-filed region. The application of phase retrieval techniques on biological samples have been assessed the strong ability of these algorithms in improving the visualization of structures and details with a complex geometry. They also produced images with a better separation of the different phases of the sample for an easier and more efficient segmentation. On the other side, as expected, the application of phase retrieval algorithms on high absorbing sample didn’t give further useful information respect to the phase contrast imaging. The Signal to Noise Ratio (SNR) values obtained for phase retrieved images, either for the area-signal and edge-signal, were significantly improved with respect to conventional phase contrast images. For both algorithms, the noise has been significantly reduced. In general, the application of TIE method produced higher SNR in comparison to Born as it is not strongly limited by absorption of the sample. We were able to reduce the scattering contributions by increasing the sample-to-detector distance and, therefore, higher SNR values were achieved. Using phase retrieval algorithms, the tiny details were less defined than in the original phase contrast image because of blurring, but, on the final analysis, this was not significant since data were rendered and segmented more efficiently. For the future development of this work, we will consider the possibility to implement a mixed TIE+Born approach in order to overcome the limitation of Born approximation about the requirement for sample absorption, and restriction posed by TIE to the near-field region sample-to-detector working distances.
Archivio
http://hdl.handle.net/10077/8585
Diritti
open access
Soggetti
  • phase contrast imagin...

  • phase retrieval

  • synchrotron radiation...

Visualizzazioni
6
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback