Logo del repository
  1. Home
 
Opzioni

Glistenings in foldable Iintraocular lenses

TOGNETTO, DANIELE
•
Sanguinetti G.
•
Toto L.
•
RAVALICO, GIUSEPPE
2002
  • journal article

Periodico
JOURNAL OF CATARACT AND REFRACTIVE SURGERY
Abstract
Purpose: To evaluate the formation of glistenings in foldable intraocular lenses (IOLs) of various materials after cataract surgery. Setting: University Eye Clinic of Trieste, Trieste, Italy. Methods: In this prospective study, 273 patients were randomized to have implantation of 1 of 7 types of foldable IOLs in the capsular bag after phacoemulsification. The IOLs were the CeeOn(R) Edge 911A (Pharmacia & Upjohn Co.), ACR6D(R) (Corneal), AcrySof(R) (Alcon), SI-40NB (AMO), Hydroview(R) H60M (Storz), Sensar(R) (AMO), and Stabibag(R) (Ioltech). The presence of glistenings in the IOL optic was assessed by slitlamp evaluation 7, 30, 90, 180, 360, and 720 days after surgery. The glistenings were graded at each control. Results: Glistenings were observed in all IOL groups. The percentage of patients with glistenings ranged from 40.0% to 67.5%, with the percentage increasing up to 90 days after surgery and then becoming stable in most groups. The AcrySof group had a continuous increase over time. The mean grade of glistenings increased up to 180 days after surgery and then became stable in most groups. The AcrySof and 911A groups had a continuous increase over time. Conclusions: Glistening formation was observed in 7 different foldable IOLs. The AcrySof group had a higher percentage and a greater density of glistenings. (C) 2002 ASCRS and ESCRS.
DOI
10.1016/S0886-3350(02)01353-6
WOS
WOS:000176815500024
SCOPUS
2-s2.0-0036068596
Archivio
http://hdl.handle.net/11368/2558862
Diritti
metadata only access
Soggetti
  • POSTERIOR CAPSULE OPA...

  • SHARP

  • EDGES

Scopus© citazioni
87
Data di acquisizione
Jun 14, 2022
Vedi dettagli
Web of Science© citazioni
84
Data di acquisizione
Mar 25, 2024
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback