Logo del repository
  1. Home
 
Opzioni

Early results with the Revitan modular revision stem

M. F. Surace
•
A. Fagetti
•
L. Donnini
altro
F. Dâ Angelo
2009
  • journal article

Periodico
JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY
Abstract
Introduction Anatomic acetabular cup, studied in 1999 by Prof. M. D’Imporzano, is born to solve the problem of acetabular revision in grade I and II mobilization (GIR), respectively, characterized by widening and deformation of cavity with eventual superior or posterior wall loss. The problem in these lesions is not such bone stock reconstruction, as correct positioning of new cup. Indeed superior wall loss can set wrong collocation of the cup tending to verticalization and superior migration of rotation centre, while posterior loss can lead to retroversion. Material and methods The hemispheric cup owns a cranial fin for iliac support with 4 holes for stabilization with spongiosa screws. In its equatorial area features 3 holes for posterior and medial screws, according to Pauwels, and circular retention cavities in order to increase the initial stability. The external shell is covered with a porous titanium layer so as to facilitate secondary osteointegration The tapered liner is in ceramic or polyethylene eventually protruded. The originality of this cup consists in having the insertion seat of the articular liner oriented by 18° in antiversion. This choice was made in order to automatically guarantee the necessary antiversion, even if the supero-posterior iliac wall is eroded, the latter being the reason why normal symmetrical revision cups lead to undesired positioning in insufficient antiversion. Considering these features, the cup can be used, as well as in revision surgery, in treatment of Coxa Profunda, Displasic Coxo-femural Osteoarthritis and acetabular fractures out-comes. In this study we present the results of 60 revisions between 2000 and 2007, with a 1–7 years follow-up. Results and conclusions The clinical outcome was good with an improvement from 55 to 88 considering the Harris Hip Score. As complications we observed only 1 case of sepsis, neither dislocation nor mobilization. Radiographical study of rotation centre pointed out a reduction of the superior migration from 1.2 to 0.8 cm after surgery. The shortness of follow-up period does not allow to conclude definitively about the effectiveness of this cup as the optimal solution in this surgery; however, we can state that it can be a valid solution for treatment of grade I and II contrasting the two principal problems of these revisions: superior migration of rotation centre and retroversion tendency.
DOI
10.1007/s10195-009-0063-5
Archivio
http://hdl.handle.net/1234/2833153
http://hdl.handle.net/11368/2833153
http://link.springer.com/article/10.1007/s10195-009-0063-5
Diritti
open access
license:creative commons
license uri:http://creativecommons.org/licenses/by/3.0/it/
FVG url
https://arts.units.it/bitstream/11368/2833153/1/art%3A10.1007%2Fs10195-009-0063.pdf
Soggetti
  • .

Visualizzazioni
5
Data di acquisizione
Apr 19, 2024
Vedi dettagli
google-scholar
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your nstitution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Realizzato con Software DSpace-CRIS - Estensione mantenuta e ottimizzata da 4Science

  • Impostazioni dei cookie
  • Informativa sulla privacy
  • Accordo con l'utente finale
  • Invia il tuo Feedback